8.8

Control Panel Installation

The following guidelines should be followed during the installation of the
control panel:
 Mount the control panel within 4.5 m of the electrical box.
 Mount the control panel on an inside wall, slightly higher than mid-
height of the cabin, in a location with freely circulating air where it can
best sense average temperature.
 Do not mount the control panel
– in direct sunlight,
– near any heat producing appliances
– in a bulkhead where temperatures radiating from behind the panel
may affect performance
– in the supply-air stream
– above or below a supply or return-air grille
Before mounting the control panel, consider the location:
➤ Create a cut out size for the control panel:
64 mm wide by 48 mm high.
➤ Plug one end of the display cable (8-pin RJ-45 connector) into the
display socket (J-2) of the electric box and the other end into the back
of the control panel.
➤ Prior to placement clean the mounting surface with isopropyl alcohol
only (test alcohol on hidden portion of surface first).
➤ Secure the control panel to a bulkhead with the adhesive strips pro-
vided.