Planning The Electrical Connections; Installation; Preparing The Toilet Location - Dometic 4300 Guide D'installation

Cuvette de toilette par gravité en céramique
Masquer les pouces Voir aussi pour 4300:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Full Ceramic Gravity Discharge Toilet
q
4 Fresh-Water System Diagram
Flush Switch/
q
Status Panel
Holding Tank
w
Status Panel
4 .2 Planning the Electrical
Connections
I
Read before proceeding:
• There must be a circuit breaker or fuse for every toilet
control. Make sure the power supply is turned off
during installation.
• For marine applications, follow ABYC guidelines.
• For RV applications, refer to ANSI/RVIA LV and
NFPA70/NEC standards (U.S.A.) or CEC I and II
standards (Canada) for the recommended wire
gauge. Refer to "1.3 Supplemental Directives" on
page 3.
• Use tinned, stranded-copper wire.
• Use crimp-type wire connections. Do not use wire
nuts, as wire nuts can corrode.
Plan all component locations so that the wires are
installed in locations that will always remain dry.
I
Several flush assembly options are available from
Dometic. Follow the instructions included with
each flush assembly.
EN
w
e
r
Gravity Toilet
e
Holding Tank
r

5 Installation

This section describes how to install the toilets.

5 .1 Preparing the Toilet Location

This section describes how to use the toilet templates to
identify and cut the required connection holes.
I
Not all toilet models have templates. Alternative
instructions are provided for the models that do not
have templates. This installation uses through-the-
floor connections.
1. Mark the hole locations.
• For 4300 and 4400 series: no template is provided
for these models. Refer to Figure 5 for hole locations.
• For the 6500 series:
– Place the floor-mounting template in the desired
location. Keep at least 11.0 in. (280 mm) between
the centerline of the template and any walls or
interior fixtures. Refer to Figure 6.
– Punch through the center of the holes and floor-
bracket corners in the template.
– Remove the template from the floor.
e
w
r
5 4300 and 4400 Series: Toilet Hole Locations
Centerline
q
Water Supply Line
w
& Electrical Wire
Access Hole
Installation
q
6 in.
(152 mm)
11.0 in.
(280 mm)
14 in.
(357 mm)
t
Rear Corner of Bowl
e
Discharge Flange
r
Access Hole
Floor
t