12.1) LOCAL COMMANDS Fig. G
Pressing the S3 key commands one START. By pressing the key again while the
automated device is moving a STOP is commanded.
13) SAFETY DEVICES
Note: only use receiving safety devices with free changeover contact.
13.1) TESTED DEVICES Fig.R
13.2) CONNECTION OF 1 PAIR OF NON-TESTED PHOTOCELLS FIG. H
14) MEMORIZING TRANSMITTERS FIG. I
RADIO
-
IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE
IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).
In the event of manual programming, the frst transmitter assigns the RECEIVER'S
KEY CODE: this code is required to subsequently clone the radio transmitters.
The Clonix built-in on-board receiver also has a number of important advanced
features:
• Cloning of master transmitter (rolling code or fxed code).
• Cloning to replace transmitters already entered in receiver.
• Transmitter database management.
• Receiver community management.
To use these advanced features, refer to the universal handheld programmer's
instructions and to the general receiver programming guide.
15) AUTOSET ADJUSTMENT FIG. I1
Enables Motor Torque to be set automatically.
If the power is suddenly disconnected and then restored the automation performs
the operations at autoset speed till the travel limits are identifed.
WARNING!! The autoset operation must be performed only once you have che-
cked that the leaf is moving accurately (opening/closing) and that the mechanical
stops are positioned correctly.
You must run an autoset cycle whenever the slow-down distance (T3) .
14 -
DEIMOS BT A 400 - DEIMOS BT A 600
INSTALLATION MANUAL
Defnition
LINE
Single-phase power supply
NEUTRAL
TRANSF PRIM
Transformer primary winding connection, 220-230V
Board power supply:
TRANSF SEC
24V~ Transformer secondary winding
MOT +
Connection motor 1
MOT -
AUX 0 -BLINKER
Contact stays closed while leaf is operating.
24V (N.O.) (MAX. 1A)
+REF SWE
Limit switch common
SWC
Closing limit switch SWC (N.C.)
SWO
Opening limit switch SWO (N.C.)
24V-
Accessories power supply output.
24V+
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
24 Vsafe+
Output active only during operating cycle.
Common
START and OPEN inputs common
START command button (N.O.).
START
Operation according to "3/4-STEP" logic
OPEN command button (N.O.).
OPEN
Gate opened with this command. If the input stays closed, the leaves stay open until the contact is opened.
When the contact is open, the automated device closes following the TCA time, where activated.
Common
STOP, PHOT and BAR inputs common
The command stops movement. (N.C.)
STOP
If not used, leave jumper inserted.
PHOTOCELL input (N.C.).
PHOT (*)
Operation according to "PHOTOCELL/PHOTOCELL DURING CLOSING" logic. If not used, leave jumper inserted.
FAULT 1
Test input for safety devices connected to PHOT.
BAR safety edge input (N.C.).
Confgurable according to the "BAR/ 8K2" logic.
BAR (*)
The command reverses movement for 2 sec.
If not used, leave jumper inserted.
FAULT 2
Test input for safety devices connected to BAR.
Antenna input.
ANTENNA
Use an antenna tuned to 433MHz. Use RG58 coax cable to connect the Antenna and Receiver. Metal bodies
close to the antenna can interfere with radio reception. If the transmitter's range is limited, move the antenna
SHIELD
to a more suitable position.
Description
220-230V ~50/60 Hz*
~
.
WARNING! While the autoset function is running, the obstacle detection function
is not active. Consequently, the installer must monitor the automated device's
movements and keep people and property out of range of the automated device.
WARNING: the torque values set by the autoset function refer to the motor force
set during the autoset cycle. If motor force is edited, an autoset opening and
closing cycle will need to be performed again.
WARNING: check that the force of impact measured at the points provided for
by standard EN 12445 is lower than the value laid down by standard EN 12453.
Setting sensitivity incorrectly can result in damage to property and injury to
people and animals.
16)REVERSING THE OPENING DIRECTION (Fig.S)
KEYS
KEYS
Description
Add Start Key
S1
associates the desired key with the Start command.
Add Pedestrian Key
S2
associates the desired key with the pedestrian command.
S2
Confrms the changes made to parameter settings and operating
>5s
Erase List
S1+S2
WARNING! Erases all memorized transmitters from the
>10s
receiver's memory.
Pressed BRIEFLY, it gives the START command.
S3