Technical Data Delhi - HASE Delhi Manuel D'utilisation

Masquer les pouces Voir aussi pour Delhi:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17

12. Technical Data Delhi 124

The Delhi 124, certified in compliance with DIN-EN 13240 and Art. 15 a B-VG (Aus-
tria), can only be operated when the fire box is closed; more than one device can be
connected to the chimney.
The following data applies to the chimney characteristics in accordance with
EN 13384-1 /-2:
Combustion Values*
Nominal Thermal Output
Room heating output
Exhaust gas temperature
Waste Gas Outlet Temp.
Waste Gas Mass Flow Rate
Min. Supply Pressure at Nominal Thermal Output
Efficiency
CO content
Particulate
OGC
NO
X
Min. Required Combustion Air Volume
* Test bench performance and values at 13% O
Depending on the insulation of the building, the nominal thermal output of 7 kW indi-
cated on 25 - 95 m² (subject to change).
Dimensions:
Height
Stove
124,5 cm
Fire box
Weight:
¹ Vertical flue pipe length
Flue pipe diameter:
44
Pipe diameter of Hase ventilation system**
2
Width
48 cm
47 cm
33 cm
Front view Delhi 124
Wood
7
kW
7,5
kW
264
˚C
350
˚C
6
g/s
12
Pa
81
%
842
mg/Nm³
22
mg/Nm³
89
mg/Nm³
Ø 42
121
mg/Nm³
Ø 48
29
m³/h
Top view Delhi 124
Depth
48 cm
32 cm
138 kg
min. 15 cm
15 cm
** For separate air supply in low-energy houses and insufficient combustion air supply in the room where
10 cm
the stove is installed.
Side view Delhi 124
Ø 27
7,5
Connection area for the inst.
of Hase air system below
Dimensions in cm