INSTRUCTIONS FOR INSTALLATION
Fitting the thermostat phial (fig. 3)
Locate the thermostat phial with the supplied bracket to
the kicking board close to the heater.When doing so take
care to avoid damaging the thermostat phial or capillary.
Fitting the casing
Hang the casing over the interior, with the back edge in
the casing supports.
The front should drop over the centring pins on the foot
supports.

Floor plate

Slide the floor plate under the appliance, positioning the
recesses around the feet of the interior.

Operations

The manufacturer has made the appliance suitable for the
type of gas as indicated on the type identification tag.The
thermostat regulates modulatingly between "full power
setting" and "low power setting" and , when little heat is
required, in two settings, i.e. "low" or "off". In this situation,
the pilot light keeps burning.The "low" setting can only be
checked when the room temperature is higher than
± 15°C (60°F).

The low setting

The low setting has been adjusted to ± 20% of the full
consumption.The low setting screw has been fully tight-
ened and is supplied with the correct low setting bore.
This is not adjustable.

Pilot light burner

Upon delivery, the pilot light burner has the correct con-
sumption by means of a nozzle inside the pilot light burn-
er.The pilot light burner needs no adjustment.
fig. 4

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS
The buttons to operate the appliance have been placed
behind the flap on the righthand side of the heater front.

Lighting

Press and hold button A (with the
symbol
). Press the ignition but-
ton E (with the symbol
or twice to light the pilot burner.
Check that the pilot flame is alight
(behind the glass on the front).
Once the pilot light is burning, hold
button A for another 10 seconds.
Then release button A and check
that the pilot light is still burning.
The main burner could be ignited
by the pilot light immediately after
button A has been released, depend-
ing on the thermostat setting, button
D, and the room temperature.
Temperature control
The thermostat setting, button D, will determine the tem-
perature in the room. Setting 7 - with '7' opposite the indi-
cator (C) - will give the highest temperature and setting 1
the lowest.The thermostat regulates the heater in modula-
tion between HIGH and LOW burner settings and, if only a
little warmth is required, between LOW and N.
The thermostat automatically keeps the room at the
required temperature.
There is absolutely no objection to the appliance staying
on overnight, it is fully protected.
The thermostat has a frost-protection setting. This is set-
ting N on the thermostat control D. If the ambient tem-
perature drops below 10 ºC, the valve will automatically
open; the heater will then heat the room to 10 ºC. If this
is not required, the heater should be switched off.

Switching off

Press button B (with the symbol o ).The gas supply to
both the main and the pilot burners is then switched off.

Important

A built-in safety lock is activated when the appliance is
switched to "OFF" (closed down setting).Therefore, wait
5 minutes before relighting the heater.Within this period,
do not try to push the lighting button, as this has been
blocked by the safety lock. Do not force the button, as this
may result in damage to the mechanism.