Glowing Coals; Fitting The Thermostat Phial; Floor Plate; Operations - Dru OPÉRA DVS 2-01 Instructions D'installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• Expel all air from the supply pipes/hoses before coupling
to the appliance.
• Do not turn the coupling tap when connecting it to the
gas supply.
• Avoid any pressure on the control tap and pipes.
• Check that all connections are gastight.
• Check that the gas pre-pressure and burner pressure
correspond with what is stated on the type plate. If nec-
essary, use the control screw to correct the burner pres-
sure. The control screw for burner pressure is located
behind the cover on the gas control. This cover can be
removed by removing the screw and clicking loose the lip
on the left side by means of a
screwdriver.

Glowing coals

The coals have already been
fitted in the factory. Should
they need replacing:
• Remove the 8 nuts.
• Remove the glass.
• Remove the broken coals.
• Evenly distribute the glowing
coals on the grille in the com-
bustion chamber (fig. 3).
• Replace the glass.
• Replace and tighten the 8 nuts.
Fitting the thermostat phial (fig. 3)
Locate the thermostat phial with the supplied bracket
to the kicking board close to the heater. When doing so
take care to avoid damaging the thermostat phial or
capillary.
Fitting the casing
Hang the casing over the interior, with the back edge in
the casing supports.
The front should drop over the centring pins on the foot
supports.

Floor plate

Slide the floor plate under the appliance, positioning the
recesses around the feet of the interior.

Operations

The manufacturer has made the appliance suitable for the
type of gas as indicated on the type identification tag. The
thermostat regulates modulatingly between "full power
setting" and "low power setting" and , when little heat is
required, in two settings, i.e. "low" or "off". In this situa-
tion, the pilot light keeps burning. The "low" setting can
only be checked when the room temperature is higher
than ± 15°C (60°F).

The low setting

The low setting has been adjusted to ± 20% of the full
consumption. The low setting screw has been fully tight-
ened and is supplied with the correct low setting bore.
This is not adjustable.

Pilot light burner

Upon delivery, the pilot light burner has the correct con-
sumption by means of a nozzle inside the pilot light burn-
er. The pilot light burner needs no adjustment.
38c-993
fig. 3
11
INSTRUCTIONS FOR INSTALLATION
fig. 4
DVS2-01