Foreword

Dear Customer,
We would like to thank you for buying this DRU prod-
uct. Our products have been designed and produced
to meet the highest possible quality, performance and
safety requirements, allowing you to enjoy years of prob-
lem-free use.
In this booklet you will find instructions for the instal-
lation and use of your new appliance. Please read these
instructions and the manual carefully to familiarize your-
self with the appliance. If you require any further support,
please do not hesitate to contact your supplier.

Unpacking

Once the heater has been unpacked, all packaging should
be disposed of in the regular manner.

Connection

This appliance should be connected by a registered
installer.

INSTRUCTIONS FOR INSTALLATION

Type of gas

This appliance can only be used and is only suitable for
the country and the type of gas mentioned on the type
identification tag. Please check that the local gas and
pressure correspond with the specifications on the type
identification tag. All regulations regarding gas installa-
tion, including any local regulations, must be observed at
all times. The appliance is to be installed by a registered
installer.
To operate the heater on bultane or propane, it should
be converted by a registered installer. A conversion set
can be ordered through him.

Important

• Keep curtains and any other flammable materials at least
50cm away form the appliance.
• Caution! Touching the heater when hot can cause burns
and blisters!
• Installation and maintenance of the appliance should be
performed by a professional certified expert with proven
knowledge and demonstrable competence in this field.
A professional expert takes all technical aspects such as
heat output and gas connection into account, as well as
the flue gas discharge requirements. The installation man-
ual will give you the information you need to install the
appliance in such a way that it will operate properly and
safely. If the installation instruction is not clear, national/
local regulations must be observed.
• Do not install any so-called dust filter on or under the
casing.
INSTRUCTIONS FOR INSTALLATION
• Do not hang wet clothes and towels etc. on the heater
to dry.
• The appliance was designed for atmospheric and heating
purposes. This means that all visible surfaces, including
the glass pane, can become hotter than 100C°. It is rec-
ommended to always place a protective grating in front
of the appliance when there are children, elderly people
or handicapped persons in the same room as the appli-
ance. If it is possible that vulnerable people are regularly
present in the room with no supervision, a fixed guard
should be mounted around the appliance.

General

The appliance can be mounted either on a wall of incom-
bustible material (e.g. stone or concrete) or on a wall of
combustible material (e.g. wood).
Installation against a non-combustible wall
Determine exactly where the convector is to be installed,
against the outer wall and standing on the floor. Lay the
aluminium floor plate on the floor and stand the convec-
tor on it, without the casing.
Slide the appliance into the required position against the
wall.
On the back of the convector is a mounting plate ((2)
fig.1) that will now be against the wall.
Mark the top and sides of the mounting plate on the wall.
By removing the mounting plate it will now serve as a
stencil to mark the exact position for the hole in the
outer wall.
To be able to hang the casing over the interior, a minimal
clearance of 25 mm must be allowed between the appli-
ance and a windowsill or suchlike.

The standard wall duct

Drill a horizontal hole in the wall, ø 230mm in diameter,
to take the air-supply pipe. The wall duct should slope at
an angle of approx. 2º.
The standard wall duct is suitable for walls with a
thickness of 50 – 330 mm and the standard extended
wall duct for walls with a thickness of 50 – 600 mm.
Depending on the thickness of the wall, the inlet and out-
let pipes should be made to length, i.e.:
• length inlet pipe = wall thickness + 20 mm.
• length outlet pipe = wall thickness + 70 mm.
The tension members fixed to the wall grid can be made
to size after installation
Mon Fitting the wall duct (fig. 1)
Push the inlet pipe (1) through the hole in the wall.
Working from the outside, fit the wall grille with the two
tension rods (4) in the inlet pipe, keeping "TOP" at the
top.
Hang the mounting plate (2) round the inlet pipe and
press it flat against the wall.