Direct Voltage (V/Dc) - VOLTCRAFT CA VC-740E Mode D'emploi

Multimètre à pince
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Direct voltage (V/DC)

Range
6.000 V
60.00 V
600.0 V
600 V overload protection; Impedance: 10 MΩ
Specified measuring range: 5–100 % of the measuring range
Alternating voltage (V/AC)
Range
6.000 V
60.00 V
600.0 V
600.0 V "LoZ"
600.0 V "Motor"
Frequency range: 40–400 Hz; 600 V overload protection; Impedance: 10 MΩ (LoZ: 300 kΩ)
Specified measuring range: 5–100% of the measuring range
The multimeter may display ≤5 counts if a measuring input is short-circuited.
After using the LoZ feature, leave the multimeter for 1 minute before using it again.
TrueRMS peak (Crest Factor (CF)) ≤3 CF to 600 V
TrueRMS peak for non-sinusoidal signals plus tolerance
CF >1.0 - 2.0
+ 3%
CF >2.0 - 2.5
+ 5%
CF >2.5 - 3.0
+ 7%
Criteria for phase detection in "Motor" mode: >80–600 V/AC, 50–80 Hz
Direct current (µA/DC)
Range
2000 µA
600 V overload protection
Automatic current limitation with integrated PTR components.
Alternating current (µA/AC)
Range
2000 µA
Frequency range: 40–400 Hz; 600 V overload protection
Automatic current limitation with integrated PTR components.
60
Resolution
0.001 V
0.01 V
0.1 V
Resolution
0.001 V
0.01 V
0.1 V
0.1 V
0.1 V
Resolution
1 µA
Resolution
1 µA
Accuracy
±(0.6% + 3)
±(0.9% + 6)
Accuracy
±(1.0% + 6)
±(2.5% + 6)
±(2.0% + 6)
Accuracy
±(0.9% + 6)
Accuracy
±(1.5% + 6)