Installation Of The Effective Load - Festo DGC-HD Notice D'utilisation

Masquer les pouces Voir aussi pour DGC-HD:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 45
DGC-HD
5.1.2

Installation of the effective load

Hard and rigid effective loads (e.g. steel):
Note
If the aluminium slide is bent against a curved effect-
ive load, the service life of the guide will be reduced.
• Make sure that the mounting surface of the effect-
ive loads is even to within t ≤ 0.01 mm.
If additional slides are used, possible differences in
height must be compensated for.
• Place the effective load in such a way that the break-down
torque resulting from force F (parallel to the axis of motion) and
lever arm "a" remains small.
• Fasten the effective load to the slide with the screws and cent-
ring sleeves.
• Make sure that the tightening torques and maximum screw-in
depth D is adhered to.
Size
Screw (lateral/top)
Max. screw-in depth D
Centring (H7)
Tightening torque
Tab. 3
Effective loads with own guide:
• Adjust the guides of the effective load and of the DGC-HD so that they are exactly parallel.
This avoids overloading of the guide and increased wear.
22
18
M5
[mm]
8.4
[mm]
9
[Nm]
5.9
Fig. 5
a
Fig. 6
Fig. 7
25
40
M6
M6
9.5
10
9
9.9
9.9
Festo – DGC-HD – 1304NH English
t
F
9