Télécharger Imprimer la page

Rechargeable Battery - Bosch GHG 18V-50 Notice Originale

Masquer les pouces Voir aussi pour GHG 18V-50:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
(3) Power level setting
(4) Unlocking switch
(5) On/off switch
(6) LED worklight
a)
(7) Battery charge indicator
a)
(8) Battery release button
a)

(9) Rechargeable battery

a)
(10) Surface nozzle
a)
(11) Angle nozzle
a)
(12) Reflector nozzle
a)
(13) Reducing nozzle
a)
(14) Heat shrink plastic tube
a) Accessories shown or described are not included with the
product as standard. You can find the complete selection of
accessories in our accessories range.
Technical Data
Heat gun
Article number
Rated voltage
Max. airflow
Temperature at the nozzle out-
A)
let
Temperature measurement ac-
curacy
Weight according to EPTA-Pro-
cedure 01:2014
Dimensions
(length × width × height)
Recommended ambient tem-
perature during charging
Permitted ambient temperature
C)
during operation
and during
storage
Recommended rechargeable
batteries (from 4 Ah)
Recommended chargers
A) At an ambient temperature of 20 °C
B) Depends on battery in use
C) Limited performance at temperatures <0 °C
Noise/vibration information
Typically, the A-weighted sound pressure level of the heat
gun is less than 70 dB(A).
Vibration total values a
(triax vector sum) and uncertainty K:
h
2
2
a
 < 2.5 m/s
, K = 1.5 m/s
.
h
Bosch Power Tools
Rechargeable battery
Inserting the Battery
Do not use force to insert the rechargeable battery.
u
The rechargeable battery is designed so that it can only
be inserted into the heat gun in the right position.
Push the charged battery into the battery holder until it
clicks into place.
The lithium-ion battery is protected against deep discharge
by "Electronic Cell Protection (ECP)". A protective circuit
switches the heat gun off when the rechargeable battery is
drained.
Follow the instructions on correct disposal.
Removing the Battery
To remove the rechargeable battery, press the battery re-
lease button and pull the battery out. Do not use force to do
this.
GHG 18V-50
Battery charge indicator
3 601 BA6 5..
The green LEDs on the battery charge indicator indicate the
state of charge of the rechargeable battery. For reasons of
V=
18
safety, you can call up the state of charge only when the heat
l/min
175
gun is off.
°C
300/500
Press the button for the battery charge indicator
show the state of charge. This is also possible when the re-
±10 %
chargeable battery is removed.
If no LED lights up after pressing the button for the battery
B)
charge indicator, then the rechargeable battery is defective
kg
0.93−2.0
and must be replaced.
Battery model GBA 18V...
mm 183 × 77 × 209
°C
0 to +35
LED
°C
–20 to +50
3 × continuous green light
2 × continuous green light
GBA 18V...
1 × continuous green light
ProCORE18V...
1 × flashing green light
GAL 18...
GAX 18...
Battery model ProCORE18V...
GAL 36...
LED
5 × continuous green light
4 × continuous green light
3 × continuous green light
2 × continuous green light
1 × continuous green light
1 × flashing green light
English | 11
or
to
Capacity
60–100 %
30–60 %
5–30 %
0–5 %
Capacity
80–100 %
60–80 %
40–60 %
20–40 %
5–20 %
0–5 %
1 609 92A 6F5 | (21.07.2021)