Record Options - Dedicated Micros ECO 9 Guide D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29

Record Options

Timed expiry
The timed expiry option allows images to be held on the disk for a selected
number of days or hours. Images on the disk which are older than this time
cannot be accessed. By default there is no timed expiry. This option can be
used to prevent the unit recording over 30 days for example.
Enable the timed expiry option, and enter the days and hours as required.
Alarm protection
Global alarm triggers can be protected automatically as they are received. If no
alarms are to be protected, select Disabled.
Pre-alarm protection
This is the amount of time the images are protected before the Global alarm is
triggered. By default this setting is 15 minutes, but this is adjustable from 00
minutes (no pre-alarm protection) to 60 minutes.
Post-alarm protection
This is the amount of time the images are protected after the Global alarm has
ended. By default this setting is 15 minutes, but this is adjustable from 00
minutes (no post-alarm protection) to 60 minutes.
Protected images
Selecting this option allows images to be protected or unprotect manually
To protect images:
1. Enter the time of the first image to be protected (in the From area).
2. Enter the time of the last image to be protected (in the To area).
3. Select 'Confirm' in the Protect images option.
4. The selected images are protected and placed in the list.