Record Schedule - Dedicated Micros ECO 9 Guide D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29

Record Schedule

Note: The Night and Weekend options are only displayed if a corresponding
Night and Weekend schedule has been configured in the Schedule menu
page.
Standard and Event PPS
Select a record rate in pictures per second (PPS) to be recorded across all
cameras. The maximum record rate is 25PPS for PAL and 30PPS for NTSC
cameras when a single camera is recorded.
The default record rate is 6PPS, this is the equivalent to a VCR in 24-hour
time-lapse mode.
To configure Eco9 to record only events (exclusive record), select the Standard
PPS as 0PPS and the Event PPS to a value you want the events to record at
for example, 3PPS. The Eco9 will then not record any cameras until activity or
the global alarm are triggered, it will then record the activity camera interleaved
with the other cameras (activity) or record all cameras on receipt of the alarm
(global alarm).
14
The table below shows the equivalent record rates of typical VCR time-lapse
modes:
Figures in brackets are for NTSC systems.
Tip: To work out the update rate per camera - the number of seconds before
the camera is updated. Divide the number of cameras by the record rate
(PPS). For example, 9 cameras with a record rate of 6PPS will be:
Update rate (seconds) = Number of cameras = 9 = 1.5 seconds
PPS
You can decrease the update rate by increasing the record rate (PPS), the only
drawback is that the recording time will also decrease.
Events active
Select whether activity is on or off for day, night, and weekend schedules.