Install the electrical T-distributor
Important!
The components of the electrical T-distributor may only be installed after the power
has been switched off.
Recommended system cable see
When using cables other than the system cable, pay attention to the different colour
code. The outer diameter must not exceed 7.5 mm.
10.20 Strip the shielding (e) off from the system lines (approx. 40 mm).
10.21 Fit the union nut (g) on the control line (f) up to the stop.
The cable cores are marked with numbers 1 through 4.
1: red
2: white
3: blue
4: black
Latch the cable cores (h) into the cable core guides (i) according to their colours.
10.22 Cut off the protruding ends of the cable core so that they are flush, i. e. so that they
do not protrude.
10.23 Place the union nut (g) on the electric T-junction (k) and tighten with the required
torque (1.2 Nm).
Caution!
Ensure correct polarity.
Each core cable colour must be in the same cable core guide on both union nuts.
When the union nut is being tightened, an electric contact and the pull-relief are
automatically established.
Special seals provide protection against dust and water.
10.24 Install the line connections between the electronic module, the solenoid-valve
cartridges and the Piezo-button.
A: Solenoid valve cartridge mixed water (Actuator 1)
B: Not used
C:Analogue output 0-10 V
D:Not used
E: Temperature sensor mixed water (optional)
F: AQUAPAY coin-operated switch (optional)
G:Piezo-button
H:Electrical T-junction, system lines (Power)
K: Electronic module
Optional:
10.25 Place the temperature sensor (l) into the water volume regulator (n).
10.26 Place the soft-binder (m) around the water volume regulator and hook it in.