Lorentz PS Série Manuel D'installation Et De Fonctionnement page 27

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Terminal Description: PS150-UL to PS200-UL / PS600 to PS4000
Figure 6: Terminal PS150-UL to PS200-UL / PS600 to PS4000
GND
+
̶
Socket
Terminal
Ground
GND
POWER IN
Well probe
Float switch
Jumper:
Battery Mode
Flow meter
Pressure sensor
Output to
motor
GND
1
2
3
4
5
6
7
Connection
connected to protective ground wire (PE)
+
connect to positive terminal of PV module
connect to negative terminal of PV module
1
connection to NC
2
connection to COM
3
connect N.O.
4
connect ground
5
connect N.C.
6
connect cable jumper for battery mode
7
connect cable jumper for battery mode
8
connect to signal
9
connect to COM
10
connect positive (+)
11
connect negative (–)
L1
connect to the L1 phase of the motor
L2
connect to the L2 phase of the motor
L3
connect to the L3 phase of the motor
connect to protective motor ground wire (PE)
Controller Installation
8
9
L1
L2
10
11
L3
GND
Table 5: Terminal explanation
Operative only
in controllers
equipped with
DataModule
25