Controller Elements; Technical Data Of The Controller - Lorentz PS Série Manuel D'installation Et De Fonctionnement

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.3 Controller Elements

ƒ Power on/off switch – The power switch is used to
start or stop the system and as a reset switch. It does not
work as power disconnect switch.
ƒ Indicator Lights – The five LED lights on the front
indicate different operational situations. For a detailed
explanation refer to chapter "10 Operating the Pump"
on page 60.
Table 2: Technical data of the PS controller
Model
Pump motor:
rated power
[kW]
PS150
0.3
Boost
PS150
0.3
PS200
0.3
PS600
0.7
PS1200
1.7
PS1800
1.7
PS4000
3.5
Affiliated pump
Max. DC input
motor
voltage
ECDRIVE 150-Boost
ECDRIVE 150-C
ECDRIVE 200-HR
ECDRIVE 600-HR
ECDRIVE 600-C
ECDRIVE 600-CS-F
ECDRIVE 1200-HR
ECDRIVE 1200-C
ECDRIVE 1200-HR
ECDRIVE 1200-C
ECDRIVE 1800-CS-F
ECDRIVE 4000-HR
ECDRIVE 4000-C
ECDRIVE 4000-CS-F
Controller Installation

7.4 Technical Data of the Controller

Refer to "Table 2: Technical data of the PS controller" on
page 19 for an overview of the most important technical
specifications of the PS controller.
Min. recommended
Vmp
[V]
[V]
50
17
50
17
100
34
150
68
200
102
200
102
375
238
19
Max.output
current
[A]
18
18
11
13
9.5
14
15

Publicité