DANUBE WED 8 Instructions Pour L'installation, L'utilisation Et La Maintenance page 90

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

24.
Cold water inlet
This serves to indicate if the cold water inlet is going to be used to fill the tub. The options
are:
Y
: the cold water inlet will be used.
N
: the cold water inlet will not be used.
25.
Decalcified water inlet
This serves to indicate if the decalcified water inlet is going to be used to fill the tub. The
options are:
Y
: the decalcified water inlet will be used.
N
: the decalcified water inlet will not be used.
26. Level 1
It determines the tub water level in the initial filling up. The possible values are:
0
: filling the tub up with water is not possible.
Min.
: the water level is the lowest possible.
Low
: indicates a water level above the minimum level.
Med.
: indicates an average water level, above the lower level.
High
: indicates a water level above the average level.
Max.
: the water level is higher than the previous level and the highest possible.
27.
Filling with movement
This serves to indicate if the drum should move while filling up with water, or if on the
contrary, it should only start to move when the water has reached a programmed level. The
options are:
Y
: the drum will move whilst filling up with water.
N
: the drum will move when the programmed water level is reached.
28. Temperature
This serves to programme the water temperature. The possible values are:
Cold
30 ºC to 90 ºC in steps of 5 ºC : the water will heat up to the specified temperature.
29. Thermal stop
This indicates if the wash time starts from reaching the programmed temperature or not.
The possible values are:
Y
: the wash time starts on reaching the programmed temperature.
N
: the wash time starts on reaching the water level.
: the water will not heat up.
46

Hide quick links:

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Wed 10Wed 13Wed 18Wed 2007Wed 25

Table des Matières