Daily Frame Transmission; Button Alarm - ADEUNIS Sigfox BREATH PM1 Guide Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Sigfox BREATH - Guide utilisateur / User guide version V1.0.0
2.4.

Daily frame transmission

The sensor send a daily frame (every 24 hours) with the following information:
Standby
FR
24h period
reached?
EN
Send frame 0x30
Example:
Register
Encoding
S300
Decimal
WARNING: the information contained in the frame are calculated with the sampling done every seconds. Then this data can be slightly different
to the data sent into the periodical frame.
2.5.

Button alarm

The product integrates a connected button that enable to send a frame when the button is activated. The button works only in event mode (no
periodical transmission).
Example:
Standby
Push button
detected ?
Number of
event reached
?
Send frame 0x51
Non
Oui
Value
1
Daily frame is activated
Register
S380
S381
In this example the product send a frame each time the button is activated.
No
NOTE: it is possible to send a frame only when a number of push button event is detected
(S381).
Example :
Yes
Register
S380
No
S381
Yes
TVOC Max in µg/m3
PM10 Max in µg/m3
PM2.5 Max in µg/m3
PM1 Max in µg/m3
This frame is also sent if a 0x05 frame is received.
Associated parameters are:
• Activation of the daily frame (register S300),
Result
Encoding
Value
Hexadecimal
0x01
Decimal
1
Encoding
Value
Hexadecimal
0x01
Decimal
5
Result
Connected button activated
The product send a frame each time
someone push the button
Result
Connected button activated
The product send a frame after 5 events
detected
Page
48
of 52

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sigfox breath pm2.5Sigfox breath pm10Sigfox breath tvoc

Table des Matières