Installing The Effective Load - Festo DGE Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 117
DGE−...−ZR/−SP

Installing the effective load

With all applications:
·
Place the effective load so that the tilting
torque of force F parallel to the movement
axis and lever arm a" remains low.
·
To design the DGE−..., use the
Festo design software Positioning Drives" è www.festo.com.
·
Leave the blue plastic cover caps fitted on the end caps. These protect the
clamping device of the band system from external influences.
Effective loads with their own guide
·
Adjust the guides of the effective load and
of the DGC so that they are exactly
parallel.
Only in this way can you avoid
overloading on the slide (permitted forces
è chapter Technical data").
Only in this way will the service life of the DGE fulfil expectations.
With hard and stiff effective loads (steel):
Note
If the aluminium slide becomes bent against
a buckled effective load, the service life of
the guide will be reduced.
· Make sure that the mounting surface of
the effective load is not bent more than as
follows:
GF: b 0.03 mm
KF: b 0.01 mm
Festo DGE−...−ZR/−SP 0909f English
a
Fig. 15
Fig. 16
Fig. 17
F
b
51

Publicité

Table des Matières
loading

Table des Matières