DGE−...−ZR/−SP
Spindle types DGE
Design
Permitted temperature range
Mounting position
Permissible effective load:
horizontal
vertical
)
Protection class **
)
Feed constant ***
Max. permitted torque *
Max. feed force
)
(theoretical) *
Max. radial force
on the drive shaft ****
Max. permitted slide speed *
Max. permitted linear
)
acceleration *
74
−18−SP
6 kg
3 kg
IP40 (cover band on top/lateral), IP42 (cover band underneath)
4 mm/rev
)
0.1 Nm
140 N
40 N
)
)
0.2 m/s
−25−SP
−40−SP
electrical linear unit with driven spindle
0 ... +40 °C (storage/operation)
Any
25 kg
50 kg
10 kg
25 kg
10 mm/rev
20 mm/rev
0.45 Nm
2.1 Nm
250 N
600 N
75 N
250 N
0.5 m/s
1.0 m/s
6 m/s
−63−SP
150 kg
75 kg
30 mm/rev
8.5 Nm
1600 N
800 N
1.2 m/s