Basic wiring diagram: Example (2)
• If link wiring is used * When multiple outdoor main units exist, remove the socket that is used
No. 1 Refrigerant circuit
No. 1 (main outdoor unit) settings
System address
No. of indoor units
(system 1 setting)
(13 units setting)
(S004)
(S002)
(S003)
ON
ON
1
2
(S005)
OFF
ON
ON
No. 2 (sub unit)
1
2
3
OFF
settings
No. of
(S006)
Unit
(S007)
Unit
outdoor units
number
ON
ON
ON
ON
number
(3 units
setting
setting
setting)
1
2
3
OFF
(unit No. 1)
1
2
3
OFF
(unit No. 2)
Leave the socket that is
Outdoor unit
Unit
used to short-circuit the
system 1
No. 1
terminal plug.
(Main)
(CN072)
Inter-outdoor unit control wiring
Inter-unit control wiring
1-1
1-2
1-3
Indoorunit
Remote controller
Remote
communication wiring
controller
No. 2
No. 1 (main unit) settings
System address
No. of indoor units
Refrigerant
(system 2 setting)
(9 units setting)
circuit
(S004)
(S002)
(S003)
ON
ON
1
2
(S005)
OFF
ON
ON
1
2
3
OFF
No. of
(S006)
(S007)
Unit number
outdoor
Unit number
ON
setting (unit
ON
ON
ON
units (2 units
setting (unit
No. 2)
setting)
1
2 3
No. 1)
1
2
3
OFF
OFF
Outdoor unit
Unit
Move the socket
system 2
No. 1
to the "OPEN" side
(CN072).
(Main)
Inter-unit control wiring
2-1
2-2
Indoor unit
To other system
link wiring
Remote controller
Remote
communication wiring
controller
Make settings as appropriate for the cases listed below.
(Refer to the instructions on the following pages.)
• Indoor and outdoor unit power can be turned ON for each system separately.
• Indoor and outdoor unit power cannot be turned ON for each system separately.
Automatic address setting in Heating mode
Automatic address setting in Cooling mode
Fig. 7-6
SUPPLEMENT
to short-circuit the terminal plug (CN072) from all outdoor main unit
PCBs except for one unit.
Alternatively, move the sockets to the "OPEN" side.
No. 3 (sub unit)
settings
(S007)
(S007)
Unit
number
ON
ON
ON
ON
setting
1
2
3
OFF
1
2
3
OFF
(unit No. 3)
Unit
Unit
No. 2
No. 3
(Sub)
(Sub)
Inter-outdoor unit control wiring
1-13
No. 2 (sub unit) settings
(S007)
ON
ON
1
2
3
OFF
Unit
No. 2
(Sub)
Inter-outdoor unit control wiring
2-9
Case 2
Case 3A
Case 3B
45
Case 2
Automatic Address Setting (no compressor operation)
● Indoor and outdoor unit power can be turned ON for each system separately.
Indoor unit addresses can be set without operating the compressors.
Automatic Address Setting from Outdoor Unit
1.
On the No. 1 (main) unit control PCB, set the unit No. switch (S007) to
On the No. 2 (sub) unit control PCB, set the unit No. switch (S007) to
On the No. 3 (sub) unit control PCB, set the unit No. switch (S007) to
2.
To set the number of outdoor units on the outdoor main unit control PCB, set the No. of outdoor units DIP switch (S006) to
ON
ON
(3 units).
1
2
3
OFF
3.
On the outdoor main unit control PCB, check that the system address rotary switch (S002) is set to "1" and that the DIP
ON
ON
switch (S003) is set to "0"
. (These are the settings at the time of factory shipment.)
1
2
OFF
4.
To set the number of indoor units that are connected to the outdoor unit to 13 on the outdoor main unit control PCB, set the
ON
ON
No. of indoor units DIP switch (S005) to "1"
1
2
3
OFF
5.
Turn on power to all indoor and outdoor units in the system.
6.
Short-circuit the automatic address pin at the outdoor main unit (CN054) for 1 second or longer, then release it.
(Communication for automatic address setting begins.)
* To cancel, again short-circuit the automatic address pin (CN054) for 1 second or longer, then release it. The LED
that indicates automatic address setting is in progress turns OFF and the process is stopped. Be sure to perform
automatic address setting again.
(Automatic address setting is completed when LEDs 1 and 2 on the outdoor main unit control PCB turn OFF.)
7.
Next turn the power ON only for the indoor and outdoor units of the next (different) system. Repeat steps 1 – 5 in the same way to
complete automatic address settings for all systems.
8.
Operation from the remote controllers is now possible.
* To perform automatic address setting from the remote controller, perform steps 1 – 5, then use the remote controller and
complete automatic address setting.
● Refer to "Automatic Address Setting from Remote Controller."
ON
1
2
3
(unit No. 1).
ON
(unit No. 2).
1
2
3
ON
(unit No. 3).
1
2
3
, and set the rotary switch (S004) to "3."
46