23. Fault Correction

Fault
Water does not flow
Water flows
continuously
Flow duration too short
or too long
Water is too hot
Water is too cold
Water flow too weak
Thermostat not
constant
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
14
Cause
– Water supply interrupted
– Water flow regulator closed
– Voltage supply interrupted
– Grit filters/Non-return valve dirty
– Piezo-button faulty
– Electronic module defective
– Solenoid valve cartridge faulty
– Solenoid valve cartridge faulty
– Flow duration setting incorrect
– Shower head calcified
– Scald-protector incorrectly set
– Thermocouple faulty
– Scald-protector incorrectly set
– Hot water is turned off
– Grit filters/Non-return valve dirty
– Hot water supply pressure too low
– Hot water temperature too low
– Thermocouple faulty
– Water volume regulator is not fully
opened
– Shower head calcified
– Grit filter/Non-return valve dirty
– Supply pressure too low
– Flow volume regulator in shower
head calcified
– Thermocouple dirty
Remedy
➯ Restore it
➯ Open it
➯ Restore it
➯ Replace them
➯ Replace it
➯ Replace it
➯ Replace it
➯ Replace it
➯ Adjust it
➯ Clean, replace if
necessary
➯ Adjust it
➯ Replace it
➯ Adjust it
➯ Open it
➯ Replace them
➯ Check it
➯ Increase it
➯ Replace it
➯ Open it
➯ Clean it
➯ Clean them
➯ Check it
➯ Clean, replace if
necessary
➯ Clean it

Publicité