Quarterly Maintenance; Battery Maintenance - Nobles SpeedGleam Manuel Opérateur

Machine à polir à système de contrôle de la poussière de 36v
Masquer les pouces Voir aussi pour SpeedGleam:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FIG. 31

QUARTERLY MAINTENANCE

(Every 250 Hours of Use)
Check the drive transaxle motor, the vacuum motor
and the brush motor for carbon brush wear. Replace
carbon brushes when worn to a length of 10 mm
(0.38 in) or less (Figure 32).
Contact an Authorized Service Center for machine
repairs.
FOR SAFETY: When servicing machine, all repairs
must be performed by a qualified service person.
WARNING: Electrical Shock Hazard.
Disconnect Battery Cables Before Servicing
Machine.
FIG. 32

BATTERY MAINTENANCE

WARNING: Fire Or Explosion Hazard.
Batteries Emit Hydrogen Gas. Keep Sparks And
Open Flame Away. Keep Battery Compartment
Open When Charging.
FOR SAFETY: When servicing machine, wear
protective gloves and eye protection when
handling batteries and battery cables. Avoid
contact with battery acid.
Nobles SpeedGleam/Plus (01- -05)
1. Check the specific gravity using a hydrometer to
determine the charge level and the condition of the
batteries (Figure 33). If one or more of the battery
cells read lower than the other battery cells (0.050
or more), the cell is damaged, shorted, or is about
to fail. Check the hydrometer readings against the
following chart to determine the remaining battery
charge level.
NOTE: Do not take readings immediately after adding
distilled water. If the water and acid are not thoroughly
mixed, the readings may not be accurate.
SPECIFIC GRAVITY
at 27_C (80_F)
1.265
1.223
1.185
1.148
1.110
NOTE: If the readings are taken when the battery
electrolyte is any temperature other than 27_C (80_F),
the reading must be temperature corrected. Add or
subtract to the specific gravity reading 0.004, 4 points,
for each 6_C (43_F) above or below 27_C (80_F).
2. Always follow proper charging instructions
(See CHARGING BATTERIES).
3. Check the electrolyte level (A) in each battery cell
after charging batteries. The level should be
approximately 1 cm from the bottom of the fill--port
(B). Add distilled water if needed (Figure 34).
DO NOT OVERFILL.
B
A
OPERATION
FIG. 33
BATTERY
CHARGE
100% CHARGED
75% CHARGED
50% CHARGED
25% CHARGED
DISCHARGED
FIG. 34