5.

Charger and battery

5.1

Technical data

5.1.1

Battery charger

Input voltage:
Output voltage:
Output current:
Weight:
5.1.2

Battery

Nominal voltage:
Number of cells:
Cell / capacity:
Weight:
5.2

Safety instructions

5.2.1
Battery charger
Caution! The following safety rules must be observed for adequate protection against
electric shocks, injures or fire hazards:
The charger must be used exclusively to charge GESIPA
Check the cord, plug and charger regularly and have them repaired by Service or by an
authorised skilled specialist electrician when damaged.
For repairs, use only genuine plugs and cords and genuine spare parts.
Never use the charger in a humid or wet environment or close to inflammable substances
or gases. Risk of explosion!
Take the charger out of its packaging before use. Insert the GESIPA
way into the charger.
Never try to charge non-rechargeable batteries.
Store the charger in a dry, closed room, out of the reach of children.
Never insert metallic parts into the charging bay - danger of short circuiting.
If the charger is wall-mounted, make sure that the inserted battery cannot fall out due to
external influences (e.g. vibrations).
This battery charger should not be operated by people with physical or mental disabilities
or impairments, nor by untrained or unskilled persons. If this is the case, they should be
supervised by someone who is responsible for safety or receive instructions from them as
to how to use the device.
100-240 V~ / 50-60 Hz
21 VDC
2.5 A
0.6 kg
18.0 V
5
Li-Ion; 2.1 Ah
Approx. 0.42 kg
batteries.
®
battery in the right
®