Tightening Torque - Wilo VeroLine-IPL Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
9.1.2 Changing the motor
(pump version with standard motor)
Dismantling
Installation
40
• Reset the fuse.
• Comply with the commissioning measures, see chapter 8 "Commis-
sioning" on page 37.
To change/dismantle the motor for pumps with a standard motor,
please refer to Fig. 3, (Item 41):
• Disconnect the system from the power and secure it against being
switched on.
• Close the shut-off valves in front of and behind the pump.
• Depressurise the pump by opening the bleed valve (Item 9).
WARNING! Danger due to extremely hot or extremely cold pressur-
ised fluid!
Depending on the temperature of the fluid and the system pres-
sure, when the venting screw is opened completely, extremely hot
or extremely cold fluid in liquid or vapour form may escape or shoot
out at high pressure.
• Always exercise caution when opening the venting screw.
• Disconnect the motor if the cable for dismantling the motor is too
short.
• Loosen the grub screws (Item 4) on the plug shaft (Item 12).
• Remove the motor by loosening the flange screws (Item 13/14/15).
To install the motor for pumps with a standard motor, please refer to
Fig. 3:
• Secure the (new) motor in place with the flange screws (Item 13/14/
15). When doing this observe the tightening torques specified in the
following table:
Screw connection
Pump
M6
housing
M10
Lantern
M8
Lantern
M10
Motor
M12
• Push the forked spacer (Fig. 4, Item A) between the lantern and plug
shaft. The forked spacer must sit there without any play.
• Secure the plug shaft (Item 12) in place with the grub screws (Item 4).
When doing this observe the tightening torques specified in the fol-
lowing table:
Screw
M6
M8
M10
• Fix the grub screws in place with adhesive (e.g.LOCK AN 302 WEICON
adhesive)
• Remove the forked spacer again.
• Connect the motor.
• Open the valves in front of and behind the pump.
• Reset the fuse.
Tightening
Installation
torque
instructions
Nm ± 10 %
10
• Tighten evenly
35
and diagonally
25
• Tighten evenly
35
and diagonally
60

Tightening torque

8 Nm
20 Nm
30 Nm
WILO SE 11/2017

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Veroline-ipl n sérieVerotwin-dplVerotwin-dpl n série

Table des Matières