This procedure applies to all models except models 50 and 63. For these, after power failure it is
necessary to wait 90 seconds for the door to be automatically unlocked.
1-H How to correct tub water level reading
Under normal conditions, water level reading needn't be corrected, but when special installation
factors like elevation ask for it, it is possible to set the zero level value in the tub as follows:
1)
Open the door.
2)
Sight-check that the tub is empty.
3)
Hold the "UP" and "DOWN" keys down simultaneously for at least 5 seconds.
4)
The DISPLAY unit will read "CALIBRATION"
5)
Confirm the value read by the card pressing the ENTER key.
6)
The BUZZER will give out a beep and the DISPLAY will resume its normal functions.
If the water level is corrected, the procedure has been carried out correctly. Otherwise the
machine will keep the zero value previously stored.
2 CYCLE STEPS
All cycles or programs stored in the card are made of a sequence of steps.
In practical terms, steps can be summarised as follows:
1 Soak
2 Prewash
3 Wash
4 Rinse
5 Spin
6 Distribution
The various programs are nothing but a definite sequence of steps to which certain level,
temperature, drum movement and other settings are associated.
The different program steps are always displayed in big print during cycle execution along with
corresponding symbol.