Service And Maintenance - Festool CLEANTEC CTM MIDI I Notice D'utilisation D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
CAUTION
Hazardous dust
Damage to the respiratory passage
► After extracting wet materials, remove the
wet filter and replace it with the main filter
for dry materials.
CAUTION
Escaping foam and fluids
► Switch off and empty the machine immedi­
ately.
8.3
Exhaust-air outlet
CAUTION
Hazardous dust
Damage to the respiratory passage
► Do not blow off any dust!
The exhaust-air outlet offers the option of di­
verting the exhaust air outside a building using
the suction hose.
► Open the grille in front of the exhaust open­
ing [1-14].
► Insert the suction hose in the exhaust open­
ing [1-14].
8.4
Cleaning the filter and filter bag
manually
► In standby mode, press the MAN but­
ton [1-17].
► Set the suction power to the maximum set­
ting [1-18].
► Cover the suction hose with your hand while
at the same time briefly pressing down the
cleaning lever [1-16] three times.
8.5
Changing the filter bag with minimal
dust
► Open the locking clips and remove the top
section of the machine [2].
► Pull the tab on the filter bag until the filter
bag opening is fully closed.
The filter bag is now securely closed and can be
removed.
► Fit the top section of the machine and close
the locking clips.
8.6
Changing the filter element
► Pull out the used filter drawer [1-15].
► Dispose of the used filter drawer in accord­
ance with statutory regulations.
► Insert the new filter drawer [1-15].
Order numbers for accessories, filters and
consumables in the Festool catalogue or
online at "www.festool.com".
NOTICE
Damage to the motor
► Never extract material without a main filter
or with a damaged main filter, as this can
damage the motor.
8.7
After finishing work
► Switch off the mobile dust extractor and
pull out the mains plug.
► Wind up the mains power cable.
► Empty the dirt trap.
► Place the suction hose [4-1] in the sealable
hose holder [1-7]. Place the mains power
cable [4-2] in the sealable hose hold­
er [1-7] or wind it up on the cord holder. To
do so, lay the power cable through the re­
cess [4-3].
► Vacuum and wipe the inside and outside of
the mobile dust extractor to clean it.
► Place the mobile dust extractor in a dry
room inaccessible to unauthorised users.
The lid of the hose holder also serves as a
storage area for tools.
9

Service and maintenance

WARNING
Risk of injury, electric shock
► Always pull the mains plug from the socket
before performing any servicing and main­
tenance work.
► All maintenance and repair work which re­
quires the motor housing to be opened
should always be carried out by an author­
ised service workshop.
Customer service and repairs must only be
carried out by the manufacturer or service
workshops: Find the nearest address at: