English
Possible causes
Suction hose blocked or kinked.
Filter bag full.
Dirty main filter.
Electronic monitoring malfunction.
Wet extraction.
7.4

Temperature cut-out

A temperature cut-out switches the mobile dust
extractor off when it reaches a critical tempera­
ture to prevent overheating. The bottom
LED [1-18] indicates a fault.
LED lights up red
► Switch off the mobile dust extractor, let it
cool down.
► Switch on the mobile dust extractor again
after approx. five minutes.
7.5
Locking the brake [1A]
► Raise the front of the mobile dust extractor
slightly.
► Push down the brake [1-13] until it engages
into position.
► Actuate the button [1-12] to release it.
7.6
SysDoc
WARNING
Risk of injury
► Do not stand on the storage area of the
mobile dust extractor.
CAUTION
Risk of injury
► Ensure that the T-Loc or the four SysDoc
locks are closed during transport.
A Systainer can be fastened to the storage
area [1-7] with the T-Loc lock [1-8]. Systainers
without T-Loc can be secured with the four Sys­
Doc locks [1-3].
18
Excessive temperature
Solution
Eliminate the block or straighten the hose.
Insert a new filter bag (see chapter
Clean the main filter (see chapter
Change the main filter (see chapter
Have the fault rectified by a Festool service work­
shop.
Function not impaired, no measures required.
8

Working

8.1
Extracting dry materials
Hazardous dust
Damage to the respiratory passage
► Always use a filter bag!
Hazardous dust
Damage to the respiratory passage
► Check that the main filter is undamaged
before extracting.
When extracting dust that exceeds the
limit value, only extract from one dust
source (power or compressed-air tool).
Observe the following when extracting dust
generated by operating power tools:
Ensure there is adequate ventilation! Observe
regional regulations!
Limit values: Exhaust air max. 50% of the fresh
air volume
Equation: room volume V
8.2
Extracting wet materials/liquids
Remove the filter bag!
Use a special wet filter.
The dust extractor stops automatically when
the maximum fill level is reached.
The bottom LED [1-18] lights up red.
► Switch off the mobile dust extractor [1-11].
► Open the locking clips [1-10] and remove
the top section of the machine.
► Empty the dirt trap [1-9].
After wet extraction, allow the main filter to dry!
Dry the mobile dust extractor before extracting
dry dust.
8.5
).
8.4
).
8.6
).
CAUTION
CAUTION
x air renewal rate L