6.2
Connecting the mobile dust extractor
WARNING
Risk of injury from uncontrolled tool start-
up
► Before switching on ensure that the con­
nected tool is switched off.
WARNING
Risk of injury from electric current
► Insert the mains plug into an earthed sock­
et.
► Do not reach into the electrical outlet mod­
ule on the mobile dust extractor.
While the mobile dust extractor is connec­
ted to the mains socket, an electric cur­
rent is running through electrical outlet
module on the mobile dust extractor at all
times.
Connecting the mobile dust extractor to a
mains socket
The mobile dust extractor is switched off.
► Connect the power cable to a mains socket.
The electrical outlet module [1-1] is live.
Switching the mobile dust extractor to standby
mode
► Press the on/off switch[1-10].
The electrical outlet module [1-1] is live.
The green LED [1-12] indicates standby
mode.
Starting the mobile dust extractor automati­
cally
The mobile dust extractor is in standby mode.
► To start the mobile dust extractor automati­
cally: Switch on the connected tool.
Starting the mobile dust extractor manually
The mobile dust extractor is in standby mode.
► Press the MAN button [1-11].
Pull the mains plug from the socket when
you are not using the mobile dust extrac­
tor and before performing any cleaning and
maintenance work.
6.3

Connecting power tools

WARNING
Risk of injury
► Observe the maximum electrical outlet
module connected load (see section "Tech­
nical data").
► Switch off the power tool.
Connecting a mains-powered power tool to the
mobile dust extractor
► Connect the power tool to the electrical out­
let module [1-1].
The power tool is connected to the mobile dust
extractor via the power cable.
7

Settings

7.1
Adjusting the suction power
► Press the plus or minus button [1-12] while
extracting.
7.2

Temperature cut-out

A temperature cut-out switches the mobile dust
extractor off when it reaches a critical tempera­
ture to prevent overheating. The bottom
LED [1-12] indicates a fault.
LED lights up red
► Switch off the mobile dust extractor, let it
cool down.
► Switch on the mobile dust extractor again
after approx. five minutes.
8

Working

8.1
Extracting wet materials/liquids
Remove the filter bag!
Use a special wet filter.
The dust extractor stops automatically when
the maximum fill level is reached.
The bottom LED [1-12] lights up red.
► Switch off the mobile dust extractor [1-10].
► Open the locking clips [1-7] and remove the
top section of the machine.
► Empty the dirt trap [1-9].
After wet extraction, allow the main filter to dry!
Dry the mobile dust extractor before extracting
dry dust.
English
Excessive temperature
13