RIDGID WD45500 Mode D'emploi page 7

Masquer les pouces Voir aussi pour WD45500:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATION
POLARIZED PLUG / ON-OFF SWITCH (Fig. 4)
To reduce the risk of electric shock, this Vac has a Polarized
Plug (one blade is wider than the other). This Plug will fit
in a Polarized Outlet only one way. If the Plug does not fit
fully in the Outlet, reverse the Plug. If it still does not fit,
contact a qualified electrician to install the proper Outlet.
Do not change the Plug in any way.
With Power Cord plugged in, turn the Vac "ON" by pressing
in on the "I" (top) on the Power Switch. To turn "OFF",
press the "O" (bottom) on the Power Switch. The symbols
used on the Switch Actuator are international "ON & OFF"
symbols.
O = OFF
Power Cord and Polarized Plug
When operating your vacuum with the Storage Lids closed,
take care to make sure that the Power Cord is positioned
through the Cover Cord Opening.
NOTE: When using the unit in the vacuuming mode, the
accessory storage lid can be used as an air diffuser by
closing this lid.
VACUUMING DRY MATERIALS
1. The Filter must always be in correct position at all times
to avoid leaks and possible damage to Vac.
2. When using your Vac to pick up very fine dust, it will
be necessary for you to empty the Drum and clean the
Filter at more frequent intervals to maintain peak Vac
performance.
NOTE: A dry Filter is necessary to pick up dry material.
If you use your Vac to pick up dust when the Filter is wet, the
Filter will clog quickly and be very difficult to clean.
SP6734-4 4.5 gallon ESF.indb 7
SP6734-4 4.5 gallon ESF.indb 7
Fig. 4
Power Switch
I = ON
Cover Cord
Opening
VACUUMING LIQUIDS
1. Vacuuming up small amounts of liquid (less than 2"
(5 cm) collected in Dust Drum) does not require Filter
removal.
2. When larger amounts of liquid are to be picked up,
remove all dry use only Paper Filter(s) and replace with
a RIDGID wet application Foam Filter. Do Not remove
the Filter Cage or Float. The Foam Filter is specifically
designed for high volume liquid pick up. If the paper
Filter is used and becomes saturated, you may see
"mist" coming from the Blowing Port
3. When the Drum is "full" the Float will rise and cut off
airflow. The motor sound will rise in pitch and its speed
will increase indicating the Drum is "full". Turn OFF the
Vac and unplug the power cord before emptying the
Drum.
4. Following use of Vac for wet pick up, allow Filter to dry
completely to avoid mildew and Filter damage.
IMPORTANT: To reduce the risk of damage to the Vac,
do not run Motor with Float in raised position.
WARNING:
!
Do not operate without filter cage and float, as
they prevent liquid from entering the impeller and
damaging the motor.