Resetting all remote control functions

Press the button T10 to reset all the remote control settings.
By doing so all of the settings of the timer are cancelled and the remote control restores all of the default settings.
Furthermore, by pressing button T10, all of the symbols indicated in fig. 29 will appear on the display, thus making it possible
to check the integrity of the display itself.
3.3.18

Managing the unit if the remote control is not available

If you cannot find the remote control, if it is faulty or the batteries are flat, the unit can work in Automatic mode only.
Use a pointed object to press the microswitch located underneath the hole on the control panel.
To switch the air-conditioner off, press the microswitch again.
To restore routing operations in the remote control, you need only issue any command once the remote control is available again.
3.4

ENERGY SAVING ADVICE

-
Always keep the filters clean (see chapter on maintenance and cleaning).
-
Keep the doors and windows closed in the air-conditioned rooms.
-
Keep sunlight out of the room by using curtains, lowering the shades or closing the shutters.
-
Do not obstruct the air flow channels (both inlet and outlet) of the unit; apart from preventing the optimal performance
of the system, this would also jeopardise correct operating and could cause irreparable damage to the unit.
3.5

DIAGNOSIS OF THE PROBLEMS

It is important for the User to distinguish between functional problems and anomalies in relation to the behaviour of the
appliance as foreseen for its normal operation. Furthermore, the most common problems may easily be solved through
simple operations on behalf of the User (See paragraph: Anomalies and solutions), while for all of the other anomalies it is
necessary to contact Xpelair.
WARNING: Please remember that any attempt to repair the appliance by unauthorised personnel will immediately
invalidate any form of guarantee.
3.5.1

Functional aspects not to be interpreted as problems

-
The compressor does not start up again immediately after a stop (it takes about three minutes to start again).
In the operating logic of the appliance a delay between a compressor stop and its successive restart has been
included, so that the compressor itself is protected against activations that are too frequent.
-
During the heating operation of the heat pump appliances, the flow of hot air may occur some minutes after activation
of the compressor.
Should the fan start at the same time as the compressor, for the first few minutes it would emit cold air into the room
(and this could bother the occupants) since the unit has not yet reached steady running conditions.