SPECIFICATIONS
Volts .............................................................120 AC
Cat. No. ...................................................... 4253-1
Amps ..................................................................6.2
No Load RPM ....................................................600
Chuck size or Taper ............................... 1/2" Chuck
Maximum Recommended Capacity
Drill ................................................................ 5/8"
Fine Thread Tap ..................................... 5/8" - 18
Coarse Thread Tap ................................. 3/8" - 16
Cat. No. ....................................................... 4262-1
Amps ................................................................11.5
No Load RPM ....................................................350
Chuck size or Taper ............................... 3/4" Chuck
Maximum Recommended Capacity
Drill ............................................................. 1-3/8"
Fine Thread Tap .......................................... 1"-14
Coarse Thread Tap ..................................... 7/8"-9
Steel Hawg™ Cutters .................................. 4" **
Cat. No. ....................................................... 4292-1
Amps ................................................................11.5
No Load RPM ........................High 750
Chuck size or Taper ................................ No. 3 M.T.
Maximum Recommended Capacity
Drill ...................................High 3/4"
Fine Thread Tap ......................................... 1" - 14
Coarse Thread Tap .................................... 7/8" - 9
Steel Hawg™ Cutters ........... High 2" *
Cat. No. ....................................................... 4297-1
Amps ................................................................11.5
No Load RPM .........................High 500
Chuck size or Taper ................................ No. 3 M.T.
Maximum Recommended Capacity
Drill ................................High 1-1/8"
Fine Thread Tap ......................................... 1" - 14
Coarse Thread Tap ....................................... 1" - 8
Steel Hawg™ Cutters .......... High 3" *
M.T. - Internal Morse Taper Socket
5/8" -11 or 1/2" -13 taps not recommended
** Requires use of 3/4" shank arbor, Cat. No. 49-57-0030
* Requires use of #3 MT Arbor, Cat. No. 49-57-0010 or 49-57-0014
SYMBOLOGY
Double Insulated
Volts
Alternating Current
Amps
No Load Revolutions per Minute (RPM)
Hertz
UL Listing for Canada and U.S.
C
US
DANGER! To reduce the risk of in-
jury, always keep hands, rags, cloth-
ing, etc. away from moving parts and
chips. Do not try to remove chips while
the cutter is rotating. Chips are sharp
and can pull objects into moving parts.

FUNCTIONAL DESCRIPTION

16
15
14
13
12
Low 375
11
Low 1-1/4"
Low 4" *
10
Low 250
1. Rack
Low 1-1/2"
2. Slide
3. Slide locking
wing screw
Low 5" *
4. Drill motor
5. Grease fitting
6. Gib adjusting
screws
7. Chuck
WARNING
removing accessories. Only use accessories
specifically recommended for this tool. Others
may be hazardous.
Attaching Feed Handles and Grips
1. Assemble the feed handles and grips to the feed
handle hub. Tighten securely.
2. To mount the feed handle to the opposite side,
remove the wing screw assembly that secures
the hub/pinion assembly. Pull out the hub/pinion
assembly and insert on the other side of the hous-
ing. Replace and tighten the wing screw assembly.
To provide maximum holding power, mount the motor
with the spindle closest to the stand. All drills (except
4253-1) can also be mounted in a reverse position
to permit drilling close to walls and corners. When
the spindle is furthest from the stand, the maximum
drill point pressure is reduced.
4
8. Housing
9. Magnet
10. Adjusting handle
11. Cord
12. Control panel
13. Control panel socket
14. Wing screw assembly
15. Feed handle
16. Feed handle grip
ASSEMBLY
To reduce the risk of injury, always
unplug tool before changing or
Mounting the Drill on Slide
1
2
3
4
5
6
7
8
9