sigfox DRY CONTACTS - Guide utilisateur / User guide version V1.2.0
Byte 8 and 9: Information on TOR4
• If configured as an input (event or Periodic mode): these bytes contain the value of the event counter of Input TOR4
• If configured as an output: current state of the output TOR4
Byte 10: Details: detailed information on the states of the TORs:
• <0> TOR1: Current state
• <1> TOR1: State at the sending of the previous frame
• <2> TOR2: Current state
• <3> TOR2: State at the sending of the previous frame
• <4> TOR3: Current state
• <5> TOR3: State at the sending of the previous frame
• <6> TOR4: Current state
• <7> TOR4: State at the sending of the previous frame
EN
In the example in grey this gives:
Byte 2 and 3=0X00F1: value of the event counter of input TOR1 equal to 241
Byte 4 and 5=0X00F1: value of the event counter of input TOR2
Byte 6 and 7=0x0001: current state of output TOR3 (because it is configured as an output in this example)
Byte 8 and 9=0x0000: input disabled in this example
Byte 10=1001 1100 (0x9C): which gives:
• <0> TOR1: Current state = 1
• <1> TOR1: State at the sending of the previous frame = 0
• <2> TOR2: Current state = 0
• <3> TOR2: State at the sending of the previous frame = 1
• <4> TOR3: Current state = 1
• <5> TOR3: State at the sending of the previous frame = 1
• <6> TOR4: Current state = 0
• <7> TOR4: State at the sending of the previous frame = 0

4.1.5 Summary of the conditions of transmission of uplink frames

The table below summarizes the conditions of the transmission of the different uplink frames:
Code
0x10
Product configuration data frames
0x20
Frames of information on the network
configuration
0x30
Keep Alive frame
0x40
Data Frame
Description
• Start-up of the product
• Exit from the configuration mode (AT Command)
• Reception of a downlink frame 0x01
• Periodically if the inputs are disabled (period defined by the resgister 301)
• Start-up of the product
• Exit from the configuration mode (AT Command)
• Reception of a downlink frame 0x02
• Start-up of the product
• Periodically if all the TORs are configured in event mode or as outputs
• Start-up of the product
• Event on an input configured in event mode
• The end of the period on input configured in periodic mode