2.2.2 Periodic transmission

The product allows the measurement and the periodic transmission of the values of the sensors according to the following diagram:
No
The settings associated with this mode of operation are:
• The transmission period (register 301).
• The configurations of the different digital inputs (registers 302 to 305).
A complete list of the registers can be found in paragraph 3.4.
E.g.:
Register
Value encoding
S301
Decimal
S302
Hexadecimal
S304
Hexadecimal
S303
Hexadecimal
S305
Hexadecimal
In this example inputs TOR1 and TOR4 are in periodic mode while TOR3 is in event mode.
Product in standby
Period
reached?
Yes
Send frame 0x40
Value
6
0x73
0x00
0xB4
0x32
Change on
digital input
?
Yes
Counting
event
Résults
Periodic mode with a period of 6x10min = 60 minutes
Input TOR1 configuration:
• Periodic mode
• Detection of high and low edges
• Waiting* period of 1 second
Input TOR2 configuration:
• Disabled
• No waiting* period
Input TOR3 configuration:
• Event mode
• Detection of high edges only
• Waiting* period of 20 second
Input TOR4 configuration:
• Periodic mode
• Counting of low edges only
• Waiting* period of 50 milliseconds