Troubleshooting

13.1. Fault lock-out
If it recognises one of the following fault features, the heater will conduct
a fault lock-out.
If several fault lock-outs occur in sequence, the heater will be disabled.
Flashing pulse signals are output by the operation indicator light for
heaters with control module 1572D. The combustion air blower and the
circulating pump will be shut down after approx. 120 seconds.
13.1.1.
Faults when the heater is switched on:
Short-circuit or break
– Water temperature sensor
– Flame sensor
– Burner motor
– Solenoid valve
13.1.2.
Faults during the start procedure:
– A flame is detected by the photo-electric controller before the high
tension ignition spark is triggered.
– No flame identified approx. 25 seconds after the heater is started.
– Short-circuit / Break or dry operation (if programmed) of the
circulating pump.
If you use the U 4855 circulating pump, the pump will cut out
automatically approx. 15 seconds after it is switched on if there is
insufficient coolant or the pump impeller is blocked automatically and
can be restarted after approx. 2 minutes.
13.1.3.
Faults whilst the heater is operating:
– The voltage level falls below the lower threshold of approx. 21 V for
a period of 20 seconds.
– Break in combustion for longer than 10 seconds.
– Short-circuit in the water temperature sensor.
– Break in the water temperature sensor.
– Short-circuit in the flame detector.
– Break in the flame detector.
– Short-circuit in the solenoid valve.
13.1.4.
Faults whilst the heater is shutting down:
Detection of a flame over than 30 seconds after the start of the shut-
down cycle, with only the circulating pump operating during the following
90 seconds.
13.1.5.
Faults due to overheating:
If the heater overheats the temperature limiter/thermostat will complete
a fault lock-out.
Depending on the heater equipment:
– The button on the temperature limiter must be reset.
– The thermostat will be reset automatically when the heater has
cooled down.
The fault lock-out can be cancelled by switching the heater off and on
again.