Thermo 230/300/350
5.4.
U 4856 (Aquavent 6000SC) circulating pump
229
±2
53
126
31
0-90°
Fig. 17: U 4856 circulating pump
installation position
NOTE:
When connecting the circulating pump it must be ensured that the
volume flow does not drop below 2500 l/h for longer than a brief pe-
riod only! Continuous operation at less than 2500 l/h will result in
undue wear of the wearing disc of the impeller!
115
60
32
0-85°
min. 5°
Installation of the circulating pump
Ø
Fig. 18: Hole pattern for the stand for U 4856 circulating pump
bar
1,1
1,0
0,9
0,8
24 V
0,7
P
0,6
0,5
0,4
0,3
0,2
0,1
0
1000
2000 3000 4000 5000 6000 7000 8000 9000
Fig. 19: Delivery rate and flow resistance
U 4856 circulating pump
Delivery rate
(with water at 20°C)
Flow resistance
(with the pump stopped)
(l/h)
Q
47