QUESTION
Is it possible to connect two
heating circuits to "Unibox E
RTL"?
How many m² of surface
temperature balance can I
connect to "Unibox E RTL"?
Can I operate "Unibox E RTL"
using an actuator?
Can I operate "Unibox E RTL"
using a remote control unit?
102273180-V02.06.2019
RESPONSE
Yes, use a "duo connector" to connect two heating circuits with
the same size to one "Unibox E RTL". Each surface tempera-
ture balance circuit can feature pipes with a maximum length of
80 m, providing you use size 16/17 pipes.
Illustr. 11: Connection diagram with two heating circuits
using "duo connector"
You can connect a surface covering approximately 20 m² per
"Unibox E RTL". The pipe length must not exceed 100 m when
using a size 17 pipe.
No, actuators are suitable for "Uniboxes" with individual room
control only. RTL valves have a different direction of control
action (e.g. "Unibox T").
No, remote control units are suitable for "Uniboxes" with indi-
vidual room control only.