MiniVent M1/100/120 F
1 .9

Performance data

The unit type plate gives an indication of the mandatory electrical values; which must be coordinated with the local
supply network. The fan performances were established on a test stand according to DIN EN ISO 5801.

1 .10 Noise data

Noise data that refers to certain distances apply to free field conditions. With regard to installation, the sound pressure
level can differ significantly from the catalogue data, as it is highly dependent on the installation conditions, i.e. on the
absorption capability of the room and the room size among other factors.
2 .0

Personnel qualification

m The electrical connection and commissioning as well as the installation, servicing and maintenance of the
fan must only be carried out by qualified electricians .
MiniVent M1/100/120 F mini fans can be used by children over the age of 8 as well as persons with physical, sensory,
or mental disabilities or lack of experience and knowledge, if they are supervised or instructed with regard to the safe
use of the unit and they understand the resulting risks. Children must not play with the unit. Cleaning or user main-
tenance must not be carried out by unsupervised children.
2 .1

Protection against contact

MiniVent M1/100/120 F mini fans do not require protection guards, since they meet the requirements from DIN EN
60335-2-80 section 20.101.
2 .2

Motor protection

The motors of the MiniVent M1/100/120 F have thermal contacts, which are wired in series with the coil and switch
off automatically and restart after cooling.
3 .0
Type overview MiniVent M1/1 . . F
M1/100 F
with automatic humidity control Ref no . 6175
M1/120 F
with automatic humidity control Ref no . 6364
3 .1

Technical data

M1/100 F
Impeller [mm]
Alternating current
Voltage/frequency
Power consumption [W]
Rated current [mA]
Flow volumes [m
/h]
3
M1/120 F
Impeller [mm]
Alternating current
Voltage/frequency
Power consumption [W]
Rated current [mA]
Flow volumes [m
/h]
3
Ø 92
Electrical supply line
1~
Protection category
230 V, 50 Hz
Protection class
9/5
Weight approx. [kg]
0.06/0.04
Speed [1/min]
90/75
Ø 111
Electrical supply line
1~
Protection category
230 V, 50 Hz
Protection class
13/10
Weight approx. [kg]
0.09/0.08
Speed [1/min]
170/150
3
NYM-O 3 x 1.5 mm²
IP45 (water jet protection)
II
0.8
2650/2250
NYM-O 3 x 1.5 mm²
IP45 (water jet protection)
II
1.05
2350/2050
EN