Performance data

The unit type plate gives an indication of the mandatory electrical values; which must be coordinated with the local
supply network. The fan performances* were established on a test stand according to DIN EN ISO 5801.

1.10 Noise data

Noise data that refers to certain distances apply to free field conditions. With regard to installation, the sound pressu-
re level can differ significantly from the catalogue data, as it is highly dependent on the installation conditions, i.e. on
the absorption capability of the room and the room size among other factors.
2.0

Personnel qualification

The electrical connection and start-up as well as installation, servicing and maintenance of the fan
must only be carried out by qualified electricians.
– MiniVent M1/100/120 P mini fans can be used by children over the age of 8 as well as persons with physical, sen-
sory, or mental disabilities or lack of experience and knowledge, if they are supervised or instructed with regard to the
safe use of the unit and they understand the resulting risks. Children must not play with the unit. Cleaning or user main-
tenance must not be carried out by unsupervised children.
2.1

Protection against contact

MiniVent M1/100/120 P mini fans do not require a protection guard, as they meet the requirements of DIN EN 60335-
2-80 section 20.101.
2.2

Motor protection device

The motors of the MiniVentM1/100/120 P are equipped with thermo contacts, which are wired in series with the win-
ding, and which automatically switch off and on again after cooling.
3.0

Type overview MiniVent M1/1.. F

M1/100 P
equipped with two speeds and presence detector
M1/120 P
equipped with two speeds and presence detector
3.1
Technical data
M1/100 P
Impeller Ø [mm]
Alternating current
Voltage/frequency
Power consumption [W]
Rated current [mA]
Flow volume [m
/h]
3
M1/120 P
Impeller Ø [mm]
Alternating current
Voltage/frequency
Power consumption [W]
Rated current [mA]
Flow volume [m
3
/h]
92
Electrical supply line
1~
Protection category
230 V, 50 Hz
Protection class
9/5
Weight approx. [kg]
0.06/0.04
Speed [1/min]
90/75
111
Electrical supply line
1~
Protection category
230 V, 50 Hz
Protection class
13/10
Weight approx. [kg]
0.09/0.08
Speed [1/min]
170/150
3
Ref.No. 6174
Ref.No. 6363
NYM-O 3 x 1.5 mm²
IP 45 (water jet protection)
II
0.8
2650/2250
NYM-O 3 x 1.5 mm²
IP 45 (water jet protection)
II
1.05
2350/2050
UK