Helios MiniVent M1/100 N/C Notice De Montage Et D'utilisation

Helios MiniVent M1/100 N/C Notice De Montage Et D'utilisation

Masquer les pouces Voir aussi pour MiniVent M1/100 N/C:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

MONTAGE- UND BETRIEBSVORSCHRIFT
INSTALLATION AND OPERATING INSTRUCTIONS
NOTICE DE MONTAGE ET D'UTILISATION
Kleinlüfter - Mini fan - Mini ventilateur
Helios MiniVent
M1/100/120 N / C
- mit codierbarem Nachlauf- und Intervallbetrieb
- with codabel overrun timer and interval operation
- avec minuterie programmable et temporisation
NR. 19052.005
NO. 19052.005
N° 19052.005
IP 45
D
UK
F

Publicité

Table des Matières
loading

Sommaire des Matières pour Helios MiniVent M1/100 N/C

  • Page 1 NOTICE DE MONTAGE ET D’UTILISATION N° 19052.005 IP 45 Kleinlüfter - Mini fan - Mini ventilateur Helios MiniVent M1/100/120 N / C - mit codierbarem Nachlauf- und Intervallbetrieb - with codabel overrun timer and interval operation - avec minuterie programmable et temporisation...
  • Page 2: Table Des Matières

    DEUTSCH Inhaltsverzeichnis KAPITEL 1. ALLGEMEINE HINWEISE ............Seite 1 Wichtige Informationen .
  • Page 3: Wichtige Informationen

    Montage- und Betriebsvorschrift MiniVent M1/100/120 N / C Wichtige Informationen KAPITEL 1 Zur Sicherstellung einer einwandfreien Funktion und zur eigenen Sicherheit sind alle nachstehenden Vorschriften genau durchzulesen und zu beachten. ALLGEMEINE HINWEISE Dieses Dokument ist Teil des Produktes und als solches zugänglich und dauerhaft aufzubewahren um einen sicheren Betrieb des Ventilators zu gewährleisten.
  • Page 4: Garantieansprüche - Haftungsausschluss

    Stillstandzeiten, starke Verschmutzung, übermäßige Beanspruchung durch klimatische, technische oder elektronische Einflüsse geeignet. Gleiches gilt für die mobile Verwendung der Ventilatoren (Fahr-, Flugzeuge, Schiffe, usw.). Ein Einsatz unter diesen Bedingungen ist nur mit Einsatzfreigabe seitens Helios möglich, da die Serienaus- führung hierfür nicht geeignet ist.
  • Page 5: Leistungsdaten

    Montage- und Betriebsvorschrift MiniVent M1/100/120 N / C Leistungsdaten Das Gerätetypenschild gibt über die verbindlichen elektrischen Werte Aufschluss; diese müssen mit dem örtlichen Ver- sorgungsnetz abgestimmt sein. Die Ventilatorleistungen wurden auf einem Prüfstand entsprechend DIN EN ISO 5801 ermittelt. 1.10 Geräuschangaben Die Geräuschangaben, die sich auf Abstände beziehen gelten für Freifeldbedingungen.
  • Page 6: Zubehör

    Montage- und Betriebsvorschrift MiniVent M1/100/120 N / C Zubehör WES 100 Wandeinbauset Best.Nr. 0717 WES 120 Wandeinbauset Best.Nr. 0486 MF 100 Montageflansch Best.Nr. 6188 TWH 100 Teleskop-Wandhülse Best.Nr. 6352 TWH 120 Teleskop-Wandhülse Best.Nr. 6353 Montageblende Best.Nr. 0281 Produktlebensdauer Dieses Gerät ist auf eine Produktlebensdauer von mindestens 40.000 h, bei S1-Betrieb mit maximaler Leistung in maximal zulässiger Umgebungstemperatur ausgelegt.
  • Page 7: Funktionsbeschreibung M1/100/120 N / C

    Montage- und Betriebsvorschrift MiniVent M1/100/120 N / C Funktionsbeschreibung M1/100/120 N / C KAPITEL 4 Mit integrierter, Intervall-Steuerung, die einen automatischen Ventilatorbetrieb in vorgegebenen zeitlichen Abständen er möglicht. Der Ventilator kann mit einem externen Schalter (evtl. mit Licht gekoppelt) mit ca. 45 sec. Anlaufverzögerung FUNKTION und ca.
  • Page 8: Reinigung

    Montage- und Betriebsvorschrift MiniVent M1/100/120 N / C Reinigung KAPITEL 5 Es sind die in Kapitel 1.2 aufgeführten Sicherheitshinweise zu beachten! – Vor Beginn der Reinigung ist sicherzustellen, dass der Ventilator allpolig vom Netz getrennt und gegen Wiederein- REINIGUNG/ schalten gesichert wurde! DEMONTAGE –...
  • Page 9: Lieferumfang / Konstruktiver Aufbau

    Montage- und Betriebsvorschrift MiniVent M1/100/120 N / C Alle nachfolgenden Informationen und Anweisungen sind nur für eine ACHTUNG autorisierte Elektrofachkraft bestimmt! Lieferumfang / Konstruktiver Aufbau KAPITEL 6 Entnehmen Sie die Liefereinheit erst unmittelbar vor dem Einbau aus dem Karton, um mögliche Beschädigungen und Verschmutzungen beim Transport sowie auf der Baustelle zu vermeiden.
  • Page 10 Montage- und Betriebsvorschrift MiniVent M1/100/120 N / C – Rohrinnendurchmesser M1/100 N / C = 100 mm bzw. M1/120 N / C = 120 mm und Abstand zu Raum-Ecken: mindestens 90 mm. – Bei Aufputzleitungsverlegung, muss die seitliche Aussparung für den Kabeleintritt (Abb.9, Pos Œ...
  • Page 11: Elektrischer Anschluss

    Montage- und Betriebsvorschrift MiniVent M1/100/120 N / C 4. Montageflansch MF 100 (Zubehör) Bei beengten Platzverhältnissen in Decken, in dünnen Wänden sowie in engen Schächten. MF 100 winkelgerecht an die Wand oder die Decke dübeln (beliebige Anzahl übereinander möglich). Anschließend Ventilator mittels beigefüg- ten Schrauben an MF 100 befestigen (Abb.
  • Page 12: Einbau

    Montage- und Betriebsvorschrift MiniVent M1/100/120 N / C – Freilauf des Laufrades prüfen WARNUNG – Alle Teile, insbesondere Schrauben, auf festen Sitz überprüfen. Schrauben dabei nicht lösen! – Beim Probelauf den Ventilator auf Vibrationen und Geräusche prüfen – Stromaufnahme mit Leistungsschildangabe vergleichen Abb.12 Abb.13 –...
  • Page 13: Betrieb

    Montage- und Betriebsvorschrift MiniVent M1/100/120 N / C Betrieb Es sind die in Kapitel 1.2 aufgeführten Sicherheitshinweise zu beachten! WARNUNG Zur Gewährleistung der einwandfreien Funktion des Ventilators, ist regelmäßig Folgendes zu prüfen: – Auftreten von Staub- oder Schmutzablagerungen im Gehäuse bzw. am Motor und Laufrad –...
  • Page 14 Montage- und Betriebsvorschrift MiniVent M1/100/120 N / C – Typen M1/100 N / C Stellung A - Auslieferzustand Kl. 1 = 75 m³/h, Aktivierung mit Zeitfunktion Kl. 2 = 90 m³/h, Aktivierung manuell Stellung B Kl. 1 = 90 m³/h, Aktivierung mit Zeitfunktion Kl.
  • Page 15: Schaltplanübersicht Für M1/100/120 N /C

    Montage- und Betriebsvorschrift MiniVent M1/100/120 N / C Schaltplanübersicht für M1/100/120 N /C SCHALTPLAN-ÜBERSICHT M1/100 N / C M1/120 N / C SS-931 Anschluss Kunde Internes Funktionsprinzip / Jumperstellung SS-931 M1/... N SS-917 M1/... NC Zeit-Eingang Manueller-Eingang a) Zeitfunktion b) manuell Ein Jumper 1 A / B Kl.1=...
  • Page 16: Kapitel 8 Instandhaltung Und Wartung

    Montage- und Betriebsvorschrift MiniVent M1/100/120 N / C Einstellung der DIP-Schalter SS-920.1 DIP-Schalter Switch / Commutateur 0 sec 45 sec Einschaltverzögerung Delayed start Démarrage temporisé 90 sec 120 sec Nachlauf / 6 min Einschaltzeit 10 min Run on time / Running time 1 2 3 4 5 6 15 min...
  • Page 17: Störungsursachen

    Netzspannung prüfen nicht Anschluss nach Schaltplan überprüfen – Laufrad blockiert Blockade lösen, reinigen, ggf. Laufrad ersetzen – Motor blockiert Helios Kundendienst kontaktieren Sicherung löst aus – Windungsschluss im Motor Helios Kundendienst kontaktieren – Zuleitung bzw. Anschluss Teile erneuern, ggf. Motor ersetzen beschädigt...
  • Page 18 Montage- und Betriebsvorschrift MiniVent M1/100/120 N / C Notizen:...
  • Page 19 Montage- und Betriebsvorschrift MiniVent M1/100/120 N / C Notizen:...
  • Page 20 HELIOS Ventilateurs · Le Carré des Aviateurs · 157 av. Charles Floquet · 93155 Le Blanc Mesnil Cedex CH HELIOS Ventilatoren AG · Tannstrasse 4 · 8112 Otelfingen GB HELIOS Ventilation Systems Ltd. · 5 Crown Gate · Wyncolls Road · Severalls Industrial Park · Colchester · Essex · CO4 9HZ...
  • Page 21 NOTICE DE MONTAGE ET D’UTILISATION N° 19052.005 IP 45 Kleinlüfter - Mini fan - Mini ventilateur Helios MiniVent M1/100/120 N / C - mit codierbarem Nachlauf- und Intervallbetrieb - with codable overrun timer and interval operation - avec minuterie programmable et temporisation...
  • Page 22 ENGLISH Table of contents CHAPTER 1. GENERAL INFORMATION ............Page 1 Important information .
  • Page 23: Important Information

    Installation and Operation Instructions MiniVent M1/100/120 N / C Important information CHAPTER 1 In order to ensure complete and effective operation and for your own safety, all of the following instructions should be read carefully and observed. GENERAL INFORMATION This document should be regarded as part of the product and as such should be kept accessible and durable to en- sure the safe operation of the fan.
  • Page 24: Warranty Claims - Exclusion Of Liability

    All versions of this documentation must be observed, otherwise the warranty shall cease to apply. The same applies to liability claims against Helios. The use of accessory parts, which are not recommended or offered by Helios, is not permitted. Any possible damages are not covered by the warranty. Changes and modifications to the unit are not per- mitted and lead to a loss of conformity, and any warranty and liability shall be excluded in this case.
  • Page 25: Performance Data

    Installation and Operation Instructions MiniVent M1/100/120 N / C Performance data The unit type plate gives an indication of the mandatory electrical values; which must be coordinated with the local supply network. The fan performances* were established on a test stand according to DIN EN ISO 5801. 1.10 Noise data Noise data that refers to certain distances apply to free field conditions.
  • Page 26: Accessories

    Installation and Operation Instructions MiniVent M1/100/120 N / C Accessories WES 100 Wall installation kit Ref.No. 0717 WES 120 Wall installation kit Ref.No. 0486 MF 100 Mounting flange Ref.No. 6188 TWH 100 Telescopic wall sleeve Ref.No. 6352 TWH 120 Telescopic wall sleeve Ref.No.
  • Page 27: Functional Description M1/100/120 N / C

    Installation and Operation Instructions MiniVent M1/100/120 N / C Functional description M1/100/120 N / C CHAPTER 4 With integrated, interval control, which enables automatic fan operation in preset intervals. The fan can be activated with an external switch (possibly connected to light) with approx. 45 sec. activation delay and approx. 6 minute over- FUNCTION run (time input)).
  • Page 28: Cleaning

    Installation and Operation Instructions MiniVent M1/100/120 N / C Cleaning CHAPTER 5 The safety instructions in chapter 1.2 must be observed! – Before cleaning, isolate the fan from the mains power supply and secure against being switched on again! CLEANING/ –...
  • Page 29: Scope Of Delivery/Design

    Installation and Operation Instructions MiniVent M1/100/120 N / C All subsequent information and instructions are intended solely for ATTENTION authorised electricians! Scope of delivery/Design CHAPTER 6 Leave the delivery unit in its box until installation. Check that the fan is in good condition and has not been damaged in transit.
  • Page 30 Installation and Operation Instructions MiniVent M1/100/120 N / C – Duct inside diameter M1/100 N / C = 100 mm or M1/120 N / C = 120 mm and distance to room corners: at least 90 mm. – With regard to surface mounted cabling, the side entry knockout for the cable (fig.9, Pos Œ...
  • Page 31: Electrical Connection

    Installation and Operation Instructions MiniVent M1/100/120 N / C 4. Mounting flange MF 100 (Accessories) If there are space restrctions in ceilings, in thin walls and in narrow shafts. Attach MF 100 to the wall or ceiling at a suitable angle (any number possible). Then fasten the fan to the MF 100 with the provided screws (fig. 10/11). Also suitable for mounting a pull-cord switch (Accessories).
  • Page 32: Mounting

    Installation and Operation Instructions MiniVent M1/100/120 N / C – Check freewheeling of the impeller WARNING – Check all parts for tightness, particularly screws, protection guards. Do not loosen screws in the process! – Check fan for vibration and noise during test run –...
  • Page 33: Operation

    Installation and Operation Instructions MiniVent M1/100/120 N / C Operation The safety instructions in chapter 1.2 must be observed! WARNING In order to ensure the smooth functioning of the fan, the following must be checked on a regular basis: – Appearance of dust or contaminant deposits in the housing or on the motor and impeller –...
  • Page 34 Installation and Operation Instructions MiniVent M1/100/120 N / C – Type M1/100 N / C Position A - factory setting Cl. 1 = 75 m³/h, activated via time function Cl. 2 = 90 m³/h, manual activation Position B Cl. 1 = 90 m³/h, activated via time function Cl.
  • Page 35: Circuit Diagram Overview For M1/100/120 N /C

    (X2 capacitor with 0,33 µF/250VAC withstrand / not provided by Helios) can be used in parallel with glow lamp. In order to not affect the electronics negatively, room lighting is to be generally connected via a...
  • Page 36: Chapter 8 Servicing And Maintenance

    Installation and Operation Instructions MiniVent M1/100/120 N / C SS-920,1 ab Platinen Ver. 006 M1/... NC DIP switch settings SS-920.1 DIP-Schalter Switch / Commutateur 0 sec 45 sec Einschaltverzögerung Delayed start Démarrage temporisé 90 sec 120 sec Nachlauf / 6 min Einschaltzeit 10 min Run on time /...
  • Page 37: Fault Causes

    Check mains voltage Check connection according to circuit diagram – Impeller blocked Clear blockade, clean, replace impeller if neces. – Motor blocked Contact Helios customer services Fuse blows – Short-circuited coil in motor Contact Helios customer services – Supply line/connection damaged...
  • Page 38 Installation and Operation Instructions MiniVent M1/100/120 N / C Notes:...
  • Page 39 Installation and Operation Instructions MiniVent M1/100/120 N / C Notes:...
  • Page 40 HELIOS Ventilateurs · Le Carré des Aviateurs · 157 av. Charles Floquet · 93155 Le Blanc Mesnil Cedex CH HELIOS Ventilatoren AG · Tannstrasse 4 · 8112 Otelfingen GB HELIOS Ventilation Systems Ltd. · 5 Crown Gate · Wyncolls Road · Severalls Industrial Park · Colchester · Essex · CO4 9HZ...
  • Page 41 NOTICE DE MONTAGE ET D’UTILISATION N° 19052.005 IP 45 Kleinlüfter - Mini fan - Mini-ventilateur Helios MiniVent M1/100/120 N / C - mit codierbarem Nachlauf- und Intervallbetrieb - with codabel overrun timer and interval operation - avec minuterie programmable et temporisation...
  • Page 42 FRANÇAIS Sommaire CHAPITRE 1. INFORMATIONS GÉNÉRALES ........... .Page 1 Informations importantes .
  • Page 43: Chapitre 1. Informations Générales

    1.2 Consignes de sécurité Des dispositions particulières sont applicables pour l’utilisation, le raccordement et le fonctionnement ; contacter Helios en cas de doute. Veiller à bien respecter les normes nationales, règlements de sécurité et instructions. Lors de la manipulation du ventilateur, veiller à bien respecter les règles de sécurité...
  • Page 44: Garantie - Réserves Du Constructeur

    à des contraintes techniques et électroniques, une demande d’approbation est requise par Helios : les modèles de série n’étant pas prévus pour cet usage. Idem pour le déplacement des ventilateurs (voi- tures, avions, bateaux, etc.).
  • Page 45: Chapitre 2. Remarques Générales

    Notice de montage et d’utilisation MiniVent M1/100/120 N / C Données des performances La plaque signalétique de l’appareil indique les valeurs de raccordement électrique nécessaires ; l’appareil doit être raccordé à l’alimentation électrique locale. Les performances du ventilateur ont été testées selon les normes DIN EN ISO 5801.
  • Page 46: Accessoires

    Notice de montage et d’utilisation MiniVent M1/100/120 N / C Accessoires WES 100 Kit de montage N° réf. 0717 WES 120 Kit de montage N° réf. 0486 MF 100 Entretoise N° réf. 6188 TWH 100 Manchon mural télescopique N° réf. 6352 TWH 120 Manchon mural télescopique N°...
  • Page 47: Chapitre 4. Fonctionnalités

    Notice de montage et d’utilisation MiniVent M1/100/120 N / C Description des fonctionnalités M1/100/120 N / C CHAPITRE 4 Avec une minuterie et une temporisation intégrée, le ventilateur peut fonctionner automatiquement pendant une durée définie à des intervalles réguliers. Commandé par un interrupteur externe (éventuellement l’interrupteur lumière), le FONCTIONNALITÉS ventilateur démarre après un délai d’env.
  • Page 48: Chapitre 5. Entretien/Démontage

    Notice de montage et d’utilisation MiniVent M1/100/120 N / C Entretien CHAPITRE 5 Bien suivre les consignes de sécurité de la section 1.2 ! – Avant de commencer toute opération d’entretien, vérifier que le ventilateur est hors tension et protégé contre tout ENTRETIEN/ redémarrage intempestif ! DÉMONTAGE...
  • Page 49: Chapitre 6. Installation

    Notice de montage et d’utilisation MiniVent M1/100/120 N / C Toutes les informations et consignes suivantes sont destinées à un ATTENTION électricien qualifié, certifié et autorisé ! Kit d’utilisation / Montage apparent CHAPITRE 6 Ne déballer qu’au moment de l’installation, afin d’éviter tous dommages et salissures lors du transport ou sur le chantier.
  • Page 50 Notice de montage et d’utilisation MiniVent M1/100/120 N / C – En cas de montage apparent, il faut briser l'encoche latérale d'entrée de câble dans le boîtier (fig. 9, Pos ) ! – Le montage du câble de raccordement assure une étanchéité parfaite. Éloigner le câble de tout objet tranchant. Fig.
  • Page 51: Raccordement Électrique

    Notice de montage et d’utilisation MiniVent M1/100/120 N / C 4. Entretoise MF 100 (accessoire) En cas d’espace restreint au plafond, dans des murs fins ou dans des gaines étroites. MF 100 permet de réduire la profondeur d’encastrement du ventilateur au mur ou au plafond (possibilité de surperposer plusieurs enretoise pour augmenter la hauteur).
  • Page 52: Montage Standard

    Notice de montage et d’utilisation MiniVent M1/100/120 N / C – Toutes les parties (vis, écrous et grille de protection inclus) doivent être fixées fermement. Ne desserrer aucune vis ! AVERTISSEMENT – Lors du test du ventilateur, contrôler les éventuels vibrations et bruits. –...
  • Page 53: Utilisation

    Notice de montage et d’utilisation MiniVent M1/100/120 N / C Utilisation Il convient de respecter les consignes de sécurité qui figurent au chapitre 1.2 ! AVERTISSEMENT Pour que le ventilateur fonctionne toujours correctement, il faut vérifier régulièrement ce qui suit : - Absence de poussière ou de saletés dans le boîtier, sur le moteur et les palles elles-mêmes.
  • Page 54 Notice de montage et d’utilisation MiniVent M1/100/120 N / C – Modèles M1/100 N / C Position A - Réglage usine Borne 1 = 75 m³/h, activation des minuteries Borne 2 = 90 m³/h, marche forcée Position B Borne 1 = 90 m³/h, activation des minuteries Borne 2 = 75 m³/h, marche forcée –...
  • Page 55 Notice de montage et d’utilisation MiniVent M1/100/120 N / C Vue d’ensemble des schémas de raccordement pour M1/100/120 N /C ENSEMBLE DES SCHÉMAS ÉLECTRIQUES SS-931 M1/100 N / C Raccordement client Principe de fonctionnement / Jumper SS-931 M1/120 N / C M1/...
  • Page 56: Chapitre 8 Entretien Et Maintenance

    Notice de montage et d’utilisation MiniVent M1/100/120 N / C Paramétrage de l’interrupteur DIP SS-920.1 DIP-Schalter Switch / Commutateur 0 sec 45 sec Einschaltverzögerung Delayed start Démarrage temporisé 90 sec 120 sec Nachlauf / 6 min Einschaltzeit 10 min Run on time / Running time 1 2 3 4 5 6 15 min...
  • Page 57: Recyclage

    – court-circuit dans le moteur Contacter le SAV Helios. déclenche – câble ou raccordement endom- Remplacer des pièces ou le moteur entier magé (Appeler le SAV de Helios). – mauvais raccordement Vérifier le raccordement, le modifier. Vibrations – encrassement Nettoyer.
  • Page 58 Notice de montage et d’utilisation MiniVent M1/100/120 N / C Notes :...
  • Page 59 Notice de montage et d’utilisation MiniVent M1/100/120 N / C Notes :...
  • Page 60 HELIOS Ventilateurs · Le Carré des Aviateurs · 157 av. Charles Floquet · 93155 Le Blanc Mesnil Cedex CH HELIOS Ventilatoren AG · Tannstrasse 4 · 8112 Otelfingen GB HELIOS Ventilation Systems Ltd. · 5 Crown Gate · Wyncolls Road · Severalls Industrial Park · Colchester · Essex · CO4 9HZ...

Ce manuel est également adapté pour:

Minivent m1/120 n/c

Table des Matières