Scope Of Delivery / Design; Preparation For Wall Or Ceiling Installation (Surface Mounted); Installation - Helios MiniVent M1/100 F Notice De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation and Operating Instructions
m
ATTENTION
CHAPTER 6

INSTALLATION

m
WARNING
MiniVent M1/100/120 F
All of the following information and instructions are only intended for an
authorised qualified electrician!
6 .0

Scope of delivery / Design

Remove the unit from the box just before installation to prevent any damage and contamination during transportation
and on site.
MiniVent M1/100/120.. F
ä
ù
ò
6 .1

Preparation for wall or ceiling installation (surface mounted)

m The safety instructions in section 1 .2 must be observed!
The fan is delivered as a complete unit as standard, i.e. ready for connection. The installation and commissioning of
the fan should take place after the completion of all other works and after the final cleaning, in order to prevent damage
and contamination of the ventilation unit.
After the removal of packaging and the start of installation, the following points must be checked:
– is there any transport damage,
– broken or bent parts
– free movement of the impeller
6 .2
Installation
The M1/100/120 F MiniVent is designed for direct wall installation. The casing must not be deformed or warped during
installation and the flatness of the installation surface must be ensured. The fans must only be installed on sufficiently
solid and stable subsurfaces with suitable fastening materials. Sufficient backflow must be ensured! If applicable, obs-
erve instructions in DIN 1946-6.
1 . Cable exit from the wall:
– The position of the cable exit is variable in the dark area (Fig.6).
– Distance to the duct centre depending on cable exit 58/68* mm with a variable position under the casing.
– For a simple assembly an exit is recommended as shown (turnable by 90° in each case).
The optimal position is 45° each if the cable exit is directly at the position of the cable grommet.
Fig .5
ò
Facia
ù
Cover of control board
ü
including 2 x fastening screws
ä
Electronic control board
ë
Plastic casing with impeller
ö
Guide vane removable at reduced installation depth
ü
Back draught shutter removable
ö
Å
Cable grommet
î
Assembly kit
Å
2x screws with plugs for wall mounting
ë
î
7