11 Dismounting
Fault
Torch mount cannot
be mounted.
CAT2 does not switch
stop signal
CAT2 does not reset
to zero position
Tab. 12
Troubleshooting
11 Dismounting
EN - 16
NOTE
• Please also consult the operating instructions for the welding
components, such as power supply, compressed air line.
Cause
• Wrong torch mount used
• Mounting flange of the CAT2
defective
• Cable between CAT2 and cable
assembly is not connected
• Cable defective
• CAT2 switch housing defective
• Mounted load is too heavy
• Mechanical defect
• Mounting parts (mount etc.) not fixed
correctly
Dismounting may only be carried out by specialized personnel. Please make
sure that the shutdown procedures are strictly observed, before the dismounting
work begins. Ensure this also for the components integrated into the welding
system.
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair
work, the following instructions must be adhered to:
• Switch off the power supply.
• Close off the compressed air supply.
• Switch off the entire welding system.
• Pull the mains plug.
Solution
• Use correct torch mount
• Send in the CAT2 for service
reparation
• Connect cable
• Replace cable
• Send in the CAT2 for service
reparation
• Reduce mounted load
• Observe the data of the
manufacturer
• Send in the CAT2 for service
reparation
• Check the fastening of the
mounting parts