Instructions to remove the Dynamic Knife Actuation
Spring Assembly (47292)
1.
Follow the Dynamic Knife Actuation Spring Assembly
Removal Instructions
Follow Steps 1-7 from "Dynamic Knife Actuation Spring
Assembly (SPA47292) Removal Instructions"
2. 2. Remove the Dynamic Knife Actuator Spring Assembly
from the Y151T-110/220 Machine
Push up against the Press Arm Assembly and keep it in place
Place a 5/16" Wrench around the Nylon Locknut
Remove the Nylon Locknut and M5 Flat Washer
Release the Press Arm Assembly into its original position.
Locate (2) Button Head Hex Socket Screw
Insert a 2.5 mm Allen Hex Key Wrench into the Button Head
Hex Socket Cap Screw
Remove all Button Head Hex Socket Cap Screw
Carefully pull out and remove the Dynamic Knife Actuator
Spring Assembly from the Y151T-110/220 Machine
3. Follow the Dynamic Knife Actuation Spring Assembly
Removal Instructions
Follow Steps 9-21 from "Dynamic Knife Actuation Spring
Assembly (SPA47292) Removal Instructions"