Thermopatch Y151 Thermo-Seal Manuel Utilisateur page 46

Masquer les pouces Voir aussi pour Y151 Thermo-Seal:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

V. 4.0 F
Oct.2015
Manual Y151 V. 4.0 FR EUR from original TPC 47117-MAN Rev 1214
Instructions to remove the Dynamic Knife Actuation
Spring Assembly (SPA47292)
1. Turn off and remove all power to the Y151T-110/220
Machine
2. Lift up the Top Cover of the Y151T-110/220 Machine
3. Remove the Label Tape Cassette and Label Tape Cassette
Rack
Locate the Label Tape Cassette and Label Tape Cassette
Rack on the left hand side of the Y151T-110/220 Machine
Insert a 4 mm Allen Hex Key Wrench into the (2) Button
Head Hex Socket Screw (21061-26-N) on the Label Tape
Cassette Rack holding the Label Tape Cassette
Remove both Button Head Hex Socket Screws and remove
the Label Tape Cassette Rack and Label Tape Cassette
4. Remove the Air Regulator/Filter /Gauge from the
Y151T-110/220 Machine
Locate the Air Regulator/Filter/Gauge on the left hand side
of the Machine
Insert a 4 mm Allen Hex Key Wrench into the Button Head
Hex Socket Screw (21061-26-N) that is holding the Air
Regulator/Filter/Gauge onto the Left Side Lower Machine
Cover
Remove the Button Head Hex Socket Screw and place the
Air Regulator/Filter/Gauge down
46