Thermopatch Y151 Thermo-Seal Manuel Utilisateur page 49

Masquer les pouces Voir aussi pour Y151 Thermo-Seal:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

V. 4.0 F
Oct.2015
Manual Y151 V. 4.0 FR EUR from original TPC 47117-MAN Rev 1214
9. Remove the Dynamic Knife Pivot Block
Locate the M5 Hex Nut Elastic Lock (21051-31-G) on the
Dynamic Knife Assembly
Insert a 8mm Wrench around the M5 Hex Nut Elastic Lock
Remove the M5 Hex Nut Elastic Lock and the Flat Washer
Locate the (2) Socket Hex Cup Point Set Screw (21049-
06-C) on top of the Stanchion, Right
Insert a 1.5 mm Allen Hex Key Wrench into the (2) Socket
Hex Cup Point Set Screw
Loosen the (2) Socket Hex Cup Point Set Screw until the
Knife Pivot Shaft (47110) can be freely pulled out
Remove the Knife Pivot Shaft and the Dynamic Knife Block
Assembly from the Y151T-110/220 Machine
Locate the (2) Button Head Hex Socket Screw (21061-
17-R) and Lock Washer (21046-03-A) that is holding the
Cutter Actuator to the Dynamic Knife Block Assembly.
Insert a 2.5 mm Allen Hex Key Wrench into the (2) Button
Head Hex Socket Screw
Remove both Button Head Hex Socket Screw
Remove the Cutter Actuator and the Blade Dynamic Knife
from the Dynamic Knife Block Assembly
49