Table 2*
Recommended separation distances between portable and mobile
RF communications equipment and the Sprint/Stroller/Hi Flow Stroller
The Sprint/Stroller/Hi Flow Stroller is intended for use in an electromagnetic environment in which
radiated RF disturbances are controlled. The customer or the user of the Sprint/Stroller/Hi Flow Stroller
can help prevent electromagnetic interference by maintaining a minimum distance between portable
and mobile RF communications equipment (transmitters) and the Sprint/Stroller/Hi Flow Stroller as
recommended below, according to the maximum output power of the communications equipment.
Rated maximum output
power of transmitter
W
0,01
0,1
1
10
100
For transmitters rated at a maximum output power not listed above, the recommended separation
distance (d) in meters (m) can be estimated using the equation applicable to the frequency of the
transmitter, where P is the maximum output power rating of the transmitter in watts (W) according
to the transmitter manufacturer.
NOTE 1 at 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
* This table is included as a standard requirement for equipment which has been tested to specific test
levels and over specific frequency ranges and been found compliant with regulations.
Table 3
Guidance and manufacturers declaration—electromagnetic immunity
The Sprint/Stroller/Hi Flow Stroller is intended for use in the electromagnetic environment specified
below. The customer or the user of the Sprint/Stroller/Hi Flow Stroller should assure that it is used in
such an environment.
Immunity test
IEC 60601 test level
Electrostatic
discharge (ESD)
IEC 61000-4-2
+- 8 kV, +- 15 kV air
Electrical fast
transient/burst
IEC 610004-4
Surge
±1 kV line(s) to line(s)
IEC 61000-4-5
±2 kV line(s) to earth
Voltage dips, short
<5% UT (>95% dip in UT)
interruptions and
voltage variations
40% UT (60% dip in UT)
on power supply
input lines
70% UT (30% dip in UT)
IEC 61000-4-11
<5% UT (>95% dip in UT)
Power frequency
(50/60 Hz)
magnetic field
IEC 61000-4-8
Note: UT is the a.c. mains voltage prior to application of the test level.
** This statement indicates that the required testing was performed in a controlled environment and the
Sprint/Stroller/Hi Flow Stroller are found to be compliant with regulations.
14 - ENG
PN MN236-C4 C | User Manual
Separation distance according to frequency of transmitter
150 kHz to 80 MHz
d=1.2√P
0.12 m
0.38 m
1.2 m
3.8 m
12 m
+- 8kV Contact
+- 2 kV, +-4 kV,
+- 8 kV, +- 15 kV air
±2 kV for power
supply lines
DC powered device
±1 kV for
input/output lines
No data input/output lines
DC powered device
for 0,5 cycle
DC powered device
for 5 cycles
for 25 cycles
for 5 sec
30 A/m
50/60 Hz
m
80 MHz and 800 MHz
d=1.2 √P
0.12 m
0.38 m
1.2 m
3.8 m
12 m
Compliance level
Electromagnetic environment—guidance
+- 8kV Contact
Floors should be wood, concrete or ceramic
+- 2 kV, +-4 kV,
tile. If floors are synthetic, the relative
humidity should be at least 30%.**
Not applicable
Not applicable
Not applicable
Not Applicable
Not Applicable
Not Applicable
Not Applicable
30 A/m
Power frequency magnetic fields should
50/60 Hz
be that of a typical commercial or hospital
environment.
800 MHz to 2,5 GHz
d=2.3 √P
0.23 m
0.73 m
2.3 m
7.3 m
23 m