GE Xcellerex XDUO Quad Single-Use Mode D'emploi page 377

Mixeur
Table des Matières

Publicité

Object
1
2
3
4
5
6
7
8
9
10
11
12
Remarque :
Xcellerex XDUO Quad Single-Use Mixeur Mode d'emploi 29-0885-07 AA
Description
PID faceplate tag name and description.
Setpoint (SP) slider and process variable (PV) display bar.
Range defining parameters.
Remarque :
See
PID control loop range defining parameters, en page 379
tion of range defining parameters.
Controlled variable (CV) slider and display.
Store button, allows to save the PID control parameters as the default tu-
ning parameters.
Reset button, allows to revert to the default tuning parameter values.
Value entry fields for PID tuning parameters:
Proportional (P)
Integral (I)
Derivative (D)
Deadband (DB)
Local/Remote mode indicator and buttons.
Remarque :
See
PID faceplate control modes, en page 378
control modes.
Auto/Manual mode indicator and buttons.
Remarque :
See
PID faceplate control modes, en page 378
control modes.
Controlled variable (CV), text field for input and output.
Setpoint (SP), text field for input and output of the set value.
Process variable (PV), the measured value of the process.
Operator-introduced changes to tuning parameters take effect imme-
diately.
B User interface description
B.2 User interface: dialog boxes
B.2.1 PID faceplate
for the descrip-
for the description of PID
for the description of PID
377

Publicité

Table des Matières
loading

Table des Matières