TROUBLESHOOTING

Circuit Breaker Trips

If you have purchased a remote control (or other equipment), make sure this equipment
was properly installed. If the problem originates from the installation of this equipment, the
warranty will not apply and you will have to pay the cost of the service call.
1. The amperage of the circuit breaker AND the electrical wiring must be as the instruction
on the pool heat pump name plate; otherwise notify your installer or electrician to
correct this problem, as this is not covered by the warranty.
2. If the circuit breaker and electrical wiring are as stated, make sure the drains located on
each side of the base of the pool heat pump are not obstructed.
The Pool Heat Pump Is Noisy
1. Check that the pool heat pump is leveled and on a solid base to prevent any vibrations
issues.
2. Ensure the noise is coming from the pool heat pump and not from other equipment
which will not be covered by the warranty (e.g.: noise coming from the bypass valve,
pool pump, etc);
3. An improper installation may cause this situation; it will need to be corrected by the
owner. This situation is not covered by the warranty.
The Temperature Shown on the Pool Heat Pump Is
Not the Same than the Pool Thermometer
It is possible to have a temperature variation between the temperature shown on the
electronic control temperature display of the pool heat pump and a pool thermometer which
may be read from different locations. Please refer to the section "Temperature Calibration",
in order to adequately recalibrate temperature if required.
Pool Heat Pump
I pg 28