Stove:
Abbrevi-
Designation
ation
a
Height
b
Width
c
Depth
Firebox:
-
Height
-
Width
-
Depth
Connections:
d
Distance from rear stove wall - flue pipe centre
e
Flue pipe diameter*
f
Flue pipe connection height
g
Flue pipe connection height top
h
Connection height for rear installation
i
External air supply, bottom connection height
/ Ø**
j
External air supply, rear connection height / Ø**
*for separate air supply in low energy houses and building ventilation
**HASE air system pipe diameter
Weights:
Stove type
Cladding
PATNA
Ceramic
PATNA
Soapstone
Heat retaining
-
block
PATNA technical data on:
Output, emissions, and chimney calculation (EN 13384-Part 1/2)
Dimensions [cm]
Test bed values*
166
61
Nominal Thermal Output
41
Room heating output
Exhaust gas temperature
27
Flue Gas Outlet Temp.
43
Flue Gas Mass Flow Rate
27
Min. Supply Pressure at Nominal Thermal Output**
Efficiency
14
CO2 content
15
CO content
min. 33
139
Particulate matter
156
OGC
16 / 10
NO
X
30 / 10
Min. required combustion air volume
Heatable living space
*at 13% O
** The additional supply pressure required for the combustion air connection with the HASE Air System:
at the back= 3 Pa
Weight [kg]
240
240
63
2
Testing fuel:
Unit
firewood
kW
7,5
kW
7,5
˚C
243
˚C
292
g/s
6,4
Pa
12
%
83
%
10,41
mg/Nm³
1250
mg/Nm³
40
mg/Nm³
120
mg/Nm³
200
m³/h
31
m
2
28-110
43
en