• Details of type and rating of fuses: 2010 T3.15 A / 250 V; 2010 T6.3 A /
250 V.
• The dehumidifier functions optimally at a room temperature of between
13 °C and 35 °C. The specified dehumidifying performance is only achiev-
able in the higher temperature range (from 22 °C) and with higher room
humidity (from 70 %). The lowest recommended operating temperature is
5 °C. In case of lower temperatures, the DEFROST mode is activated too
frequently. The highest operating temperature is 35 °C and the relative
humidity is 80 %.
Setting up / operation
Note: Make sure that there is always sufficient space between the dehu-
midifier and the wall or other large objects (> 50 cm). The air flow must not
be blocked by objects of any kind.
1. Remove the air inlet grille (16) on the back by reaching into the recess in
the lower area of the grille and tilting the grille away from the device.
Take the HEPA filter (18) out of the housing (1), remove the plastic film
and reinsert the filter into the device. Arrows on the top of the filter (18)
indicate the direction in which the filter must be inserted. Place the grille
(16) back into the housing.
2. Place Lukas Pro on a flat surface in the desired area. Plug the mains
cable (2) to a socket with the correct voltage rating (see rating label on
the device).
3. Press the On/Off button (4) to turn on the dehumidifier.
4. In "DRY" mode (5), the dehumidification level 2 and the hygrostat in
continuous operation („CO") are preset. The swing function is activated.
In addition, the Wi-Fi function is switched on and the device is in pairing
mode. All functions can be changed manually. The "DRY" mode is acti-
vated by default when you put the device into operation. You can also
activate/deactivate the air purification mode by pressing the "PURIFY"
button (7). If the LED above the "PURIFY" button (7) lights up, the air
purification mode is activated. Once the desired humidity has been
reached, the compressor switches off and the appliance continues to
run in air purification mode only. You can adjust the speed of the fan by
pushing the "SPEED" button (8).
5. In "LAUNDRY" mode (6), the swing function, dehumidification level 4
and the hygrostat on continuous operation ("CO") are preset. The timer
is programmed to 6 hours by default but can be changed manually. The
other functions cannot be changed in this mode. The remaining operat-
ing time is indicated on the display.
6. To activate the air purification mode, press the "PURIFY" button (7). If
the air purification mode is active, the LED above the "PURIFY" button
(7) lights up. In this mode, the air is purified without the dehumidification
function. The air quality is measured by the particle sensor and indi-
cated by the LED display (25) on the front of the housing. The white LED
indicates good air quality. The yellow LED indicates medium air quality
and the red LED indicates poor air quality. If the device is switched on
again, the display lights up in yellow for the first 3 seconds. The display
then changes to the currently measured air quality (white, yellow or red).
7. You can select the speed of the fan in the dehumidifier by pushing the
button for selection of dehumidification level ("SPEED") (8). There are
4 dehumidification levels. The levels are displayed as bars (level 1 = 2