English
1 . Safety Instructions
WARNING!
Before using or maintaining this product, it is important to read the
following safety instructions. If you fail to follow and implement all
the specified instructions and procedures, you will invalidate the
warranty and Zaptec Charger AS will not be liable for any claims for
compensation.
!
Read these instructions carefully and examine the equipment to
familiarise yourself with the product prior to use.
!
This equipment may only be installed, repaired and maintained
by qualified personnel.
!
All applicable local, regional and national regulations must
be followed when installing, repairing and maintaining this
equipment.
!
Do not use this product if it is damaged. See the section Support
and Repairs for further information.
!
Do not use an extension lead on the charging cable.
!
Do not touch the plugs or insert foreign objects into them.
!
Do not insert measuring pins, wires or anything else into the
quick-release connector on the charging station. Contact your
electrician for testing.
!
EVSE adapters must not be used unless specified and approved
by the vehicle manufacturer.
6
2 . Technical Specifications
Electrical
Parameter
Test condition
Standby power
consumption
TN 3 phase @ 32 A
TN 1 phase @ 32 A
Maximum charging
power
IT 3 phase @ 32 A
IT 1 phase @ 32 A
Connectivity
Protocol
Supported standards
4G
LTE Cat M1
Wi-Fi
802.11 b/g/n
Bluetooth
Bluetooth v5.1 (BR/EDR/BLE)
Powerline (PLC)
HomePlug Green PHY, 10 Mbit/s
Plug and charge
Hardware support for ISO15118
RFID
ISO/IEC 14443 A (Type A)
ISO/IEC 15693
Integrated energy meter
Parameter
Test condition
Line voltage, current,
and power factor
Accuracy
Line voltage, current, power
factor and temperature
MID model only: integrated energy meter
Parameter
Certification
Harmonized Standard
Notified Body
Rated Voltage
Rated Current
Optical Test Output (must be activated in the app)
English
Min
Typ
Max
Unit
3
W
22
7.4
kW
12.7
7.4
Maximum
Operating
transmit power
frequencies
23 dBm
B3, B8, B20, B28
17 dBm
2.4–2.4835 GHz
10 dBm
2.4–2.4835 GHz
H-field at 3 m:
13.56 MHz
–9.5 dBµA/m
Min
Typ
Max
Unit
-2
2
%
-3
3
%
Value
MID Class B
EN 50470-1:2006, EN 50470-3:2006
Justervesenet (0431) / NMi Certin (0122)
3 x 230/400 V
0.25-5 (32) A
10000 imp/kWh
7